Electrical Requirements - Maytag MLE24PDAGW Instructions Manual

27" commercial single-load electric stack dryer
Hide thumbs Also See for MLE24PDAGW:
Table of Contents

Advertisement

Available languages

Available languages

Product Dimensions
Top dryer
exhaust
225 mm
(8
")
7
8
940 mm
(37")
127 mm (5")
Door
603 mm
(23
")
3
4
460 mm
(18
")
1
8
Electric
1054 mm
(41
")
1
2
83 mm
(3
")
1
4
Bottom
Back View
dryer
exhaust
737 mm (29")
686 mm (27")
1940 mm
(76
")
3
8
approx. 25 mm
(1")
Side View
343 mm
This dryer is supplied without an electric cord and plug. It must
(13
")
1
2
be connected by a competent electrician to a single-phase
electricity supply at the voltage shown on the dataplate, using
a suitable fixed wiring installation in accordance with local and
national wiring regulations.
n A 3-wire cord of minimum conductor size 6 mm
section area should be used.
n A 45A supply fuse should be used, and a switch having
a contact separation in both poles that provides full
disconnection under over-voltage category III conditions must
be incorporated into the fixed wiring in accordance with local
wiring regulations. The dryer should be positioned so that the
disconnection switch is clearly visible and easily accessible to
the user. This disconnection switch also provides the function
of an emergency stop control for the user.
n A cord clamp bushing is provided on the dryer, and should
be tightened on completion of wiring. The electrical mains
terminals are located behind the small rear access panel
(terminal block cover), and connections should be made in
accordance with the terminal markings. Remember to replace
the terminal access panel (terminal block cover).
NOTE: In accordance with the European EMC Directive
(2004/108/EC), the maximum electricity supply system
impedance to which the electric dryer should be connected
is declared to be 0.012 Ohm + J0.007 Ohm.
NOTE: Electrical safety standards: The manufacturer has
chosen compliance with IEC/EN.60335 standards as the most
appropriate for this product.
If codes permit and an additional earth bond wire is used, it is
recommended that a qualified electrician determine that the earth
bond path is adequate.

Electrical Requirements

cross-
2
5