Installation Requirements; Tools And Parts; Location Requirements - Maytag MLE24PDAGW Instructions Manual

27" commercial single-load electric stack dryer
Hide thumbs Also See for MLE24PDAGW:
Table of Contents

Advertisement

Available languages

Available languages

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Tools needed
200 mm (8") or 250 mm
n
(10") Pipe wrench
200 mm (8") or 250 mm
n
(10") adjustable wrench
Flat-blade screwdriver
n
Phillips screwdriver
n
Adjustable wrench that
n
opens to 25 mm (1") or
hex-head socket wrench
Level
n
Parts supplied
Remove parts bag from dryer drum. Check that all parts were
included.
Foot boot (4)
n
Dryer foot (4)
n
NOTE: The circuit diagram for this dryer is located inside the
lower front panel, within the Tech Sheets.
Technical
Specifications:
220 – 240 V, 50 Hz. AC
9150W
Total mass: 125 kg max.
NOISE: Sound Pressure Level, Lpa: 58 dBA
(uncertainty, Kpa: +/–10 dBA).
4

INSTALLATION REQUIREMENTS

8 mm (5/16") socket
n
wrench
Utility knife
n
Vent clamps
n
Caulk gun and caulk
n
(for installing new
exhaust vent)
Pliers
n
Putty knife
n
Clothes Capacity:
9 kg max. each dryer

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
n Check code requirements: Some codes limit or do not permit
installation of clothes dryers in garages or sleeping quarters.
Contact your local building inspector.
NOTE: The dryer must not be installed in an area where it will be
exposed to water and/or weather.
Recessed Area Installation Instructions
This dryer may be installed in a recessed area.
This dryer must not be installed in a closet with a door.
The installation spacing is in millimeters and is the minimum
allowable. Additional spacing should be considered for ease
of installation, servicing, and compliance with local codes and
ordinances.
The dryer must be exhausted outdoors.
No fuel-burning appliance may be installed in the same recess
as the dryer.
Minimum Installation Clearances
Back
Sides
Recessed 51 mm
0 mm
(2")
51 mm (2")
305 mm
(12")
0 mm (0")
Recessed
side view
Additional clearances for wall, door, and floor moldings may be
required or if external exhaust elbow is used.
Top
Front
305 mm
(0")
(12")
0 mm
Recessed
front view
(0")
0 mm (0")