Technical Data - Baxi Solo 2 PF Installation And Servicing Instruction

Wall mounted powered flue gas fired central heating unit
Table of Contents

Advertisement

2.0
Technical Data – Page 5
Model
Heat Output (Max)
Heat Output (Min)
Heat Input (Max)
Heat Input (Min)
Burner Pressure
(Max)
Burner Pressure
(Min)
Gas Rate
(after 10 mins)
Lifting Weight
Water Content
Outercase
Dimensions
Flue Terminal
Dimensions
Static Head
Connections
Heat Exchanger
Low Head
System Design
Gas Connection
Electrical Supply
Controls
Internal Fuse
30
kW
8.9
Btu/h
30,000
kW
5.86
Btu/h
20,000
kW
10.99
Btu/h
37,500
kW
7.33
Btu/h
25.000
mbar
16.0 ± 0.5
in wg
6.4 ± 0.2
mbar
8.0 ± 0.5
in wg
3.2 ± 0.2
3
3
CV 38MJm
1.04m
/h
3
36.86ft
/h
kg
23.1
lbs
51
Litres
1.1
pints
1.9
Height
600mm
Width
350mm
Depth
287mm
Diameter
100mm
Depth
65mm
Max
30 metres (100 ft)
Min
1 metres (3.25 ft)
Flow
22mm Cu tail
Return
22mm Cu elbow
Cast iron monobloc
Min
0.2m (8 in)
fully pumped open vented and sealed systems
RC ½ ( ½ in BSPT)
230V - 50Hz fused 5A - 90W
boiler thermostat, pilot & electronic flame sensing, timed pump over-run,
frost protection thermostat
4AF 250V to BS4256 situated on control board
40
50
11.72
14.65
40.000
50,000
9.09
12.02
31,000
41,000
14.65
18.32
50.000
62,500
11.36
15.02
38,750
51.250
16.0 ± 0.5
16.0 ± 0.5
6.4 ± 0.2
6.4 ± 0.2
10.0 ± 0.5
11.5 ± 0.5
4.0 ± 0.2
4.4 ± 0.2
3
3
1.39m
/h
1.74m
/h
3
3
49.0ft
/h
61.3ft
/h
23.1
23.1
51
51
1.1
1.1
1.9
1.9
600mm
600mm
350mm
350mm
287mm
287mm
5
60
70
17.58
20.5
60,000
70,000
14.95
17.88
51,000
61,000
21.98
25.64
75,000
87,500
18.68
22.35
63.750
76,250
16.0 ± 0.5
16.0 ± 0.5
6.4 ± 0.2
6.4 ± 0.2
11.5 ± 0.5
12.1 ± 0.5
4.4 ± 0.2
4.8 ± 0.2
3
3
2.08m
/h
2.78m
/h
3
3
73.5ft
/h
98.1ft
/h
32.2
32.2
71
71
1.6
1.6
2.8
2.8
600mm
600mm
462mm
462mm
287mm
287mm
80
23.45
80,000
20.8
71,000
29.31
100,000
26.01
88,750
16.0 ± 0.5
6.4 ± 0.2
11.5 ± 0.5
4.4 ± 0.2
3
2.78m
/h
3
98.1ft
/h
34.2
75.5
1.3
2.3
600mm
462mm
287mm

Hide quick links: