Baxi Solo 2 PF Installation And Servicing Instruction page 11

Wall mounted powered flue gas fired central heating unit
Table of Contents

Advertisement

4.0
Site Requirements – Page 11
Terminal Position with Minimum Distance
A
Directly below an openable window or other
opening, e.g. an air brick.
B
Below gutters.
C
Below eaves, soil pipes or drain pipes.
D
Below balconies or car port roof
E
From vertical drain pipes and soil pipes.
F
From internal or external corners.
G
Above ground, roof or balcony level.
H
From a surface facing a terminal.
I
From a terminal facing a terminal.
J
Vertically from a terminal on the same wall.
K
Horizontally from a terminal on the same wall.
L
For an opening in a car port (e.g. door, window)
into a dwelling.
Table 2
4.3 Flue Position (Ctd)
WARNING - The addition of anything that may
interfere with the normal operation of the appliance
(e.g. FLUE DAMPERS, ECONOMISERS.etc.) without
the express written permission of Baxi Heating Ltd
could invalidate the appliance warranty and infringe
the GAS SAFETY (Installation and Use)
REGULATIONS.
If a terminal is less than 2 metres (78 ¾ in) above a
balcony, above ground or above a fiat roof to which
people have access then a suitable terminal guard
must be provided.
6. Table 2 and the accompanying diagram show the
positioning of the flue terminal relative to buildings and
other structures.
7. The dimensions of the flue terminal are shown in
Fig. 12.
(mm)
4.4 Flue Dimensions
300
1. The standard flue supplied with the appliance is
suitable for use with flue lengths between 100mm (4in)
25
and 685mm (27in).
75
200
NOTE: Maximum flue length when flued to the left or
75
right is
25
300
584mm (23 n) - 30, 40, 50 PF
600
533mm (21 in) - 60, 70, 80 PF
1200
1500
2. Flue extension kits are available as an optional extra
300
for installations up to 1 metre (39
1200
metres (79 ¾ in). 2 metre kit is not available for the 70
and 80 PF model.
3. A vertical flue kit, with flue breaker, is also available as
an optional extra (Sol-Ver Kit).
4. Where it is intended to pass the flue through a
combustible wall or timber framed dwelling, reference
should be made to British Gas publication DM2.
5. If the flue is more than 1.8 metres (70
required that it is supported.
6. All above dimensions are taken from the
respective faces of the outer case.
11
3
/
in) and up to 2
8
7
/
in) long, it is
8