Lantech IES-2008 User Manual

Lantech IES-2008 User Manual

8 10/100tx with x-ring management industrial switch

Advertisement

Quick Links

8 10/100TX with X-Ring Management
Industrial Switch
IES-2008
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Lantech IES-2008

  • Page 1 8 10/100TX with X-Ring Management Industrial Switch IES-2008 User Manual...
  • Page 2 Notice: This manual contents are based on the below table listing software kernel version, hardware version, and firmware version. If the switch functions have any different from the manual contents description, please contact the local sale dealer for more information. Firmware Version V1.06 Kernel Version...
  • Page 3 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 4: Table Of Contents

    Content Introduction ..............1 Features ..............1 Package Contents ............ 2 Hardware Description ..........3 Physical Dimension ..........3 Front Panel ............... 3 Reset Button ..............4 Bottom View ............. 4 DIP-switch ..............4 LED Indicators ............6 Ports ................. 7 Cabling ..............
  • Page 5 Wall Mount Plate Mounting ........14 Hardware Installation..........15 Network Application ..........16 Redundant ring Application ........16 Coupling Ring Application ........17 Dual Homing Application ........18 Web-Based Management ........19 About Web-based Management......19 Preparing for Web Management ......19 System Login............
  • Page 6 Power Alarm Configuration ..........35 IP Configuration............35 SNTP Configuration ..........36 IP Security .............. 39 RSTP Configuration ..........40 Redundant ring ............44 QoS Configuration..........46 IGMP ..............48 SNMP Configuration..........49 Security Manager ........... 51 Configuration Backup ..........52 TFTP Update Firmware..........
  • Page 7: Introduction

    Introduction The 8 10/100TX with redundant ring Web management industrial switch is a cost- effective solution and meets the high reliability requirements demanded by industrial applications. The 8 10/100TX with redundant ring Web management industrial switch can be easily managed through the Web GUI. It also provides the redundant ring function that can prevent the network connection failure.
  • Page 8: Package Contents

    Simple Network Time protocol supported Management IP security TFTP firmware update and system configuration restore and backup 1Mbits Embedded memory 2K MAC address table NMP, Web management, RMON supported Package Contents Please refer to the package content list below to verify them against the checklist.
  • Page 9: Hardware Description

    Hardware Description In this paragraph, we will introduce the Industrial switch’s hardware spec, port, cabling information, and wiring installation. Physical Dimension 8 10/100TX with redundant ring Web management industrial switch dimension (W x H x D) is 54mm x 135mm x 105mm Front Panel The Front Panel of the 8 10/100TX with redundant ring Web management industrial switch is showed as following figure.
  • Page 10: Reset Button

    Reset Button The reset button provides user a quick and easy way to restart and set the configuration back to default value. Restart: press the button for 2 seconds and release. Set to factory default value: press the button for 5 seconds and release. The switch will set all configurations back to default setting.
  • Page 11 DIP Switch No Status Description Disable port 1 Alarm Enable port 1 Alarm. If the port’s link fails, the fault LED will light up. Disable port2 Alarm Enable port 2 Alarm. If the port’s link fails, the fault LED will light up. Disable port3 Alarm Enable por3 t Alarm.
  • Page 12: Led Indicators

    Disable port8 Alarm Enable port8 Alarm. If the port’s link fails, the fault LED will light up. Disable the ring master function. Enable the switch as the ring master in the redundant ring group. [NOTE] When port alarm function is enabled, the fault LED will on and Alarm relay will activity when port failure occurs.
  • Page 13: Ports

    No Power failure or UTP port failure or Fiber port failure occurs The industrial switch is the master of Green redundant ring group. R. M. (Ring Master) The industrial switch is not a ring master in redundant ring group. Green The port is linking.
  • Page 14 RJ-45 Pin Assignments Pin Number Assignment [NOTE] “+” and “-” signs represent the polarity of the wires that make up each wire pair. All ports on this industrial switch support automatic MDI/MDI-X operation, you can use straight-through cables (See Figure below) for all network connections to PCs or servers, or to other switches or hubs.
  • Page 15: Cabling

    Cross Over Cable Schematic Cabling Use four twisted-pair, Category 5 cabling for RJ-45 port connection. The cable between the converter and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long.
  • Page 16: Wiring The Power Inputs

    Wiring the Power Inputs Please follow below steps to insert the power wire. V- V+ V- V+ 1. Insert the positive and negative wires into the V+ and V- connector on the terminal block connector. 2. To tighten the wire-clamp screws for preventing the DC wires to loose.
  • Page 17: Wiring The Fault Alarm Contact

    Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as below figure shows. By inserting the wires and set the DIPswitch at “ON” status, it will detect when power is failure or port link failure and form an open circuit. And, the following figure shows an application example for the fault alarm contact.
  • Page 18: Mounting Installation

    Mounting Installation DIN-Rail Mounting The DIN-Rail is screwed on the industrial switch when out of factory. If the DIN-Rail is not screwed on the industrial switch, please see the following figure to screw the DIN-Rail on the switch. Follow the below steps to hang the industrial switch.
  • Page 19 First, insert the top of DIN-Rail into the track. Then, lightly push the DIN-Rail into the track. Check the DIN-Rail is tightly on the track. To remove the industrial switch from the track, reverse steps above.
  • Page 20: Wall Mount Plate Mounting

    Wall Mount Plate Mounting Follow the below steps to mount the industrial switch with wall mount plate. 1. Remove the DIN-Rail from the industrial switch; loose the screws to remove the DIN-Rail. 2. Place the wall mount plate on the rear panel of the industrial switch. 3.
  • Page 21: Hardware Installation

    Hardware Installation In this paragraph, it will describe how to install the 8 10/100TX with redundant ring Web management industrial switch and the installation points for attention. 1. Unpack the Industrial switch. 2. Check the DIN-Rail is screwed on the Industrial switch. If the DIN-Rail is not screwed on the Industrial switch.
  • Page 22: Network Application

    Network Application This chapter provides some sample applications to help user to have more actual idea of industrial switch function application. A sample application of the industrial switch as below: Redundant ring Application The industrial switch supports the redundant ring protocol that can help your network system to recovery from network connection failure within 300ms or less, and make your network system more reliable.
  • Page 23: Coupling Ring Application

    Coupling Ring Application In the network, it may have more than one redundant ring group. By using the coupling ring function can connect each redundant ring for the redundant backup. It can ensure the transmissions between two ring groups will no failure. A sample of coupling ring application figure as below:...
  • Page 24: Dual Homing Application

    Dual Homing Application Dual Homing function is to prevent the connection lose between redundant ring group and upper level/core switch. The Dual Homing function only work when the redundant ring function is active. The maximum Dual Homing port is one in a redundant ring group.
  • Page 25: Web-Based Management

    Web-Based Management This section introduces the configuration and functions of the Web-Based management. The following configuration steps are based on the firmware version 1.06. About Web-based Management On CPU board of the switch there is an embedded HTML web site residing in flash memory, which offers advanced management features and allow users to manage the switch from anywhere on the network through a standard browser such as Microsoft Internet Explorer.
  • Page 26: System Login

    Default Gateway: 192.168.16.254 User Name: root Password: root System Login Launch the Internet Explorer on the PC. Key in “http:// “+” the IP address of the switch”, and then Press “Enter”. The login screen will appear right after. Key in the user name and password. The default user name and password is “root”.
  • Page 27: Port Status

    Port status Display every port status which depended on user’s setting and the negotiation result. Port: the port number Type: the speed mode, ex: 100TX = 100Mbps Link: “Down” means “No Link”. “UP” is for “Link” State: Display port statuses “disable” or “enable”. “Unlink” will be treated as “off”...
  • Page 28: Port Statistics

    Port information interface Port Statistics Display the current port statistic information. Click Clear button to clean all counts. Port Statistics Interface...
  • Page 29: Port Control

    Port Control Modifying the port status Select the port by scroll the Port column State: disable or enable control of his port Negotiation: set auto negotiation mode is Auto, Nway (specify the speed/duplex on this port and enable auto-negotiation), or Force Speed: Set the speed of the port Duplex: Set the port with full-duplex or half-duplex mode Flow control: Set flow control function is Symmetric or Asymmetric in...
  • Page 30: Port Mirroring

    bytes. System Location: Assign the switch physical location. The maximum length is 64 bytes. System Description: Display the description of switch. Read only cannot be modified. Firmware Version: Display the switch’s firmware version. Kernel Version: Display the kernel software version. Hardware version: Display the switch hardware version.
  • Page 31: Vlan Configuration

    Analysis Port: the mirror port will receive all monitored port traffic. The mirror port can connect with the LAN analyzer or Netxray. Monitor Port: the ports which user wants to monitor. All monitor port traffic will be copied to mirror port. Maximum 7 monitor ports can be selected in one switch.
  • Page 32 network devices to another Layer 2 switch. However, all the network devices are still plugged into the same switch physically. The industrial switch supports port-based and 802.1Q (tagged-based) VLAN. In the default configuration, VLAN operation mode default is “disable”. VLAN Configuration interface Port-based VLAN Packets can go among only members of the same VLAN group.
  • Page 33 VLAN – PortBase interface Click to add a new VLAN group. The maximum VLAN group is up to 64 VLAN groups Enter the VLAN name, group ID and group the members of VLAN group Click Apply...
  • Page 34 VLAN—PortBase Add interface The VLAN group list will display right after. Click Next Page to view other VLAN groups. button to delete unwanted VLAN. Delete button to modify existing VLAN group. Edit [NOTE] Remember to execute the “Save Configuration” action, otherwise the new configuration will lose when the switch power off.
  • Page 35 contains a VLAN Identifier (VID) that indicates the VLAN numbers. All ports on the switch belong to default VLAN, VID is 1. The default VLAN can’t be deleting. The maximum VLAN group is up to 64 VLAN groups. 802.1q VLAN interface Basic Click button...
  • Page 36 different VLAN groups and one of VLAN group ID is equal to the assigned Management VLAN ID, it still has the right to remote management the switch. Group Name: Assign a name for the new VLAN VLAN ID: Fill in a VLAN ID (2~ 4094). The default is 1 Select ports from the ports list, and then, click to group the port as a VLAN group...
  • Page 37 Set the outgoing frames are VLAN-Tagged frames or untagged, and then click Apply Tag: outgoing frames with VLAN-Tagged Untag: outgoing frames without VLAN-Tagged Port VID: Configure port VID settings Port VLAN ID: Enter the port VLAN ID Click Apply To reset to default value, click Default button...
  • Page 38: Alert

    802.1q VLAN – Port VLAN ID interface [NOTE] Remember to execute the “Save Configuration” action, otherwise the new configuration will lose when the switch power off. Alert There are three kinds of alert – e-mail, event, and power alarm. You can configure each alert function, as you needed.
  • Page 39: Event Configuration

    SMTP Server IP Address: Set up the mail server IP address Authentication: Mark the check box to enable and configure the email account and password for authentication Mail Account: Set up the email account to receive the alert. Ex: johnadmin@123.com. The email account must exist on the mail server, which user had set up in SMTP Server IP Address column Password: The email account password Confirm Password: reconfirm the password...
  • Page 40 System event selection: 4 selections – Device cold start, Power status, SNMP Authentication Failure, and Redundant ring topology changes. Mark the checkbox to select the event. When selected events occur, the system will sent out the alerting. Device cold start: when the device executes cold start action, the system will send out the alert to the dedicate SMTP server.
  • Page 41: Power Alarm Configuration

    Event Configuration interface Power Alarm Configuration Power alarm function enables the Relay alarm action. Without enabling power alarm function, the Relay alarm action will not work even the Relay alarm is set. Mark the check box and click Apply button. Power Alarm interface IP Configuration Configure the IP Settings and DHCP client function, and then click...
  • Page 42: Sntp Configuration

    apply the new IP settings. DHCP Client: Enable or Disable the DHCP client function. When DHCP client function is enabling, the industrial switch will be assigned the IP address from the network DHCP server. The default IP address will be replace by the DHCP server assigned IP address.
  • Page 43 SNTP Client: enable or disable SNTP function to get the time from the SNTP server Daylight Saving Time: enable or disable daylight saving time function. When daylight saving time is enabling, user need to configure the daylight saving time period UTC Timezone: Set the switch location time zone.
  • Page 44 CET - Central European FWT - French Winter MET - Middle European +1 hour 1 pm MEWT - Middle European Winter SWT - Swedish Winter EET - Eastern European, +2 hours 2 pm USSR Zone 1 BT - Baghdad, USSR +3 hours 3 pm Zone 2...
  • Page 45: Ip Security

    Daylight Saving Period: Configure the daylight saving time period Daylight Saving Offset (mins): Configure the offset value Click Apply [NOTE] Remember to execute the “Save Configuration” action, otherwise the new configuration will lose when the switch power off. SNTP Configuration IP Security IP security function allows user to assign 10 specific IP addresses which have permission to access the switch through the web browser for the securing...
  • Page 46: Rstp Configuration

    [NOTE] Remember to execute the “Save Configuration” action, otherwise the new configuration will lose when the switch power off. IP Security Interface RSTP Configuration The Rapid Spanning Tree Protocol (RSTP) is an evolution of the Spanning Tree Protocol and provides for faster spanning tree convergence after a topology change.
  • Page 47 parameters Priority (0-61440): a value used to identify the root bridge. The bridge with the lowest value has the highest priority and is selected as the root. If the values change, user has to reboot the switch. The value must be multiple of 4096 according to the protocol standard rule. Max Age (6-40): the number of seconds a bridge waits without receiving Spanning-tree Protocol configuration messages before attempting a reconfiguration.
  • Page 48 RSTP– System Configuration Interface Per Port Configuration Configuring the path cost and priority of every port 1. Select the port in Port column 2. Path Cost: The cost of the path to the other bridge from this transmitting bridge at the specified port. Enter a number 1 through 200000000. 3.
  • Page 49 P2P disabling. 5. Admin Edge: The port directly connected to end stations cannot create bridging loop in the network. To configure the port as an edge port, set the port to “True” status. 6. Admin Non Stp: The port includes the STP mathematic calculation. True is not including STP mathematic calculation.
  • Page 50: Redundant Ring

    Redundant ring Redundant ring provide a faster redundant recovery than Spanning Tree topology. The action is similar with STP or RSTP, but the algorithms not the same. In the redundant ring topology, every switch should enable redundant ring function and assign two member ports in the ring. Only one switch in the redundant ring group would be set as a backup switch that one of two member ports would be blocking, called backup port, and another port is called working port.
  • Page 51 level/core switch. Enable Redundant ring: To enable the redundant ring function. Marking the check box to enable the redundant ring function. & 2 Working Ports: Assign two ports as the member ports. One port will be working port and one port will be the backup port. The system will automatically decide which port is working port and which port is backup port.
  • Page 52: Qos Configuration

    time. 2. Remember to execute the “Save Configuration” action, otherwise the new configuration will lose when the switch power off. QoS Configuration Configure Qos setting of the every port. Oos Policy: Select the Qos policy rule Using the 8,4,2,1 weight fair queue scheme: the switch will follow 8:4:2:1 rate to process priority queue from Hi to lowest queue.
  • Page 53 When the packet received by port 1, the system will check the TOS value of the received IP packet. If the TOS value of received IP packet is 25(priority = high), and then the packet priority will have highest priority. [NOTE] QoS and Rate control cannot be existed at the same time.
  • Page 54: Igmp

    IGMP The Internet Group Management Protocol (IGMP) is an internal protocol of the Internet Protocol (IP) suite. IP manages multicast traffic by using switches, routers, and hosts that support IGMP. Enabling IGMP allows the ports to detect IGMP queries and report packets and manage IP multicast traffic through the switch.
  • Page 55: Snmp Configuration

    IGMP Snooping interface SNMP Configuration The SNMP is a Protocol that governs the transfer of information between management and agent. The switch supports SNMP V1. Define management stations as trap managers and to enter SNMP community strings. Also, define a name, location, and contact person for the switch. Fill in the system options data, and then click Apply to update the changes.
  • Page 56 Community strings Community strings serve as password for MIB read or write. Strings: Fill the name of string RO: Read only. Enables requests accompanied by this string to display MIB-object information RW: Read write. Enables requests accompanied by this string to display MIB-object information and to set MIB objects Click Trap Manager...
  • Page 57: Security Manager

    SNMP Management interface Security Manager Changing web management login user name and password for the management security issue User name: key in the new user name. The default is “admin” Password: key in the new password. The default is “admin” Confirm password: re-enter the new password Click Apply...
  • Page 58: Configuration Backup

    Security Manager interface Configuration Backup Restore the backup configuration back to the industrial and backup the switch configuration to TFTP server. TFTP Restore Configuration The restore flash ROM value can be restored from TFTP server, but the backup image has to be on the TFTP server. The industrial switch will download the image back to the flash from the TFTP server.
  • Page 59: Tftp Update Firmware

    TFTP Backup Configuration Saving current flash ROM value from the industrial switch to the TFTP server, then go to the TFTP restore configuration page to restore the image value back to the industrial switch. TFTP Server IP Address: Fill in the TFTP server IP Backup File Name: Fill the file name Click Apply...
  • Page 60: Factory Default

    TFTP Update Firmware interface Factory Default Reset switch to default configuration, except the IP address, subnet mask, default gateway, username, and password will remain as user had been configured. Click button to reset switch to default setting. Default Factory Default interface Save Configuration Save the industrial switch configuration to the flash memory.
  • Page 61: System Reboot

    System Reboot Reboot the switch in software reset. Click Reboot button to reboot the switch. System Reboot interface Rate Control Set up every port’s bandwidth rate and packet limitation type. Limit Packet type: select the packet type that wants to filter. The packet types have all type packet, broadcast/multicast/unknown unicast packet, broadcast/multicast packet,...
  • Page 62: System Log

    [NOTE] 1. Remember to execute the “Save Configuration” action, otherwise the new configuration will lose when the switch power off. 2. Qos and Rate control cannot be existed at the same. Rate Control Interface System Log Set up system log events and view the system log events. System Log Configuration Reload Viewing the system log events.
  • Page 63 Click Apply button to apply the configuration System Log Configuration interface Event Configuration Select the system log events. When selected events occur, the system will send out the log information. Also, per port log events can be selected. System event selection: 4 selections – Device cold start, Power status, SNMP Authentication Failure, and Redundant ring topology change.
  • Page 64 system will produce a log message Power status: when the device power status has changed, the system will produce a log message SNMP Authentication Failure: when the SNMP authentication fails, the system will produce a log message Redundant Ring topology change: when the redundant ring topology has changed, the system will produce a log message Port event selection: select the per port events.
  • Page 65: Troubles Shooting

    Troubles shooting Verify that is using the right power cord/adapter (DC 12-48V), please don’t use the power adapter with DC output bigger than 48V, or it will burn this switch down. Select the proper UTP cable to construct your network. Please check that you are using the right cable.
  • Page 66: Technical Specification

    Technical Specification The 8 10/100TX with redundant ring Web management industrial switch technical specification is following. IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX Fast Ethernet IEEE802.3x Flow Control and Back-pressure Standard IEEE802.1d spanning tree / IEEE802.1w rapid spanning tree IEEE802.1p class of service IEEE802.1Q VLAN Tag Protocol CSMA/CD...
  • Page 67 Packet throughput 2.38Mpps @64bytes (8TX) ability Per port: Link/Activity (Green), Full duplex/Collision (Yellow) Per unit: Power (Green) Power 1 (Green) Power 2 (Green) Fault (Yellow) Master (Green) 10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable EIA/TIA-568 100-ohm (100m) Network Cable 100Base-TX: 2-pair UTP/STP Cat.
  • Page 68 RFC 1213 MIBII RFC 1493 Bridge MIB RMON RFC 1757 RFC 2674 VLAN MIB RFC 1643 Ethernet like MIB SNMP MIB RFC1215 Trap MIB IGMP MIB. Private MIB for switch information, redundant ring, port alarm, TFTP firmware upgrade, reset, port mirror, IP security Up to 3 Trap stations Cold start, Port link Up, Port link down, Authentication Failure...
  • Page 69 IEEE802.1d spanning tree Spanning tree IEEE802.1w rapid spanning tree IGMP v1 and Query mode IGMP Up to 256 groups Simple network time protocol SNTP Simple mail transfer protocol SMTP 1000 event log entries System Event Log IP address security to prevents unauthorized Management IP security intruder...
  • Page 70 Provide DIN rail kit and wall mount ear for wall Install mount or DIN-type cabinet install Provides one relay output for port breakdown, power fail and provide DIPswitch to mask link Alarm down port. Alarm Relay current carry ability: 1A @ DC24V Support ingress packet filter and egress packet limit.
  • Page 71 FCC Class A, CE EN61000-4-2 (ESD), CE EN61000-4-3 (RS), CE EN-61000-4-4 (EFT), CE EN61000-4-5 (Surge), CE EN61000-4-6 (CS), CE EN61000-4-8, CE EN61000-4-11, CE EN61000-4-12, CE EN61000-6-2, CE EN61000-6-4 Safety UL, cUL, CE/EN60950-1 IEC60068-2-32 (Free fall), IEC60068-2-27 Stability testing (Shock), IEC60068-2-6 (Vibration)

Table of Contents