Page 1
IPES/IES-5416T Series 16 10/100TX + 4 1000T L2 (w/8 or 16 PoE at/af) Industrial Managed Switch w/ITU G.8032 Ring User Manual (Hardware) IP-67 IP-54 IP-43 Sept. 2017...
Page 2
Recommendation for Shielded network cables STP cables have additional shielding material that is used to reduce external interference. The shield also reduces the emission at any point in the path of the cable. Our recommendation is to deploy an STP network cable in demanding electrical environments. Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where large inductive loads such as motors or contactors are in close vicinity to the camera or its cable.
Page 3
Lantech Communications Global Inc. Products offered may contain software which is proprietary to Lantech Communications Global Inc. The offer or supply of these products and services does not include or infer any transfer of ownership.
Page 4
FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy.
Chapter 1 Introduction Lantech IES-5416T & IPES-5416T-8 (IP67/IP43) series is a high performance L2 IP67/IP43 industrial Gigabit uplink switch with 8x10/100TX + 2 GigaT + 2Dual Speed Giga FX (w/8 PoE at/af injectors-IPES model)by M12 connectors which provides L2 wire speed and advanced security function for connecting PD network.
Page 7
Jumbo frame 10KB on all ports Connectors 10/100TX: 16 x ports M12 4-pole D-coded with Auto MDI/MDI-X function 10/100/1000T: 4 x ports M12 8-pole A-coded with Auto MDI/MDI- –X X function (for model, is 4 x ports M12 8-pole X-coded with Auto MDI/MDI-X function) RS-232 connector: 1 x M12 5-pole A-coded...
Page 8
Power Max. 13W 12V~48VDC input Consumption Max. 16W 72VDC/ 110VDC input Case IP67 model: Aluminum case Dimension 285mm(W)x200mm(H)x84.4mm(D) IP43 model: Aluminum case 273mm(W)x187mm(H)x84.4mm(D) Weight 2.1kgs(IP67); 1.8kgs (IP43) Installation DIN Rail** and Wall Mount Design EMI & EMS FCC Class A, CE EN55022 Class A, CE EN55024, CE EN61000-4-2, CE EN61000-4-3, CE EN61000-4-4, CE EN61000-4-5, CE EN61000- 4-6, CE N61000-4-8, EN61000-4-11...
Page 9
IEEE802.1p Class of Service IEEE802.1Q VLAN Tag IEEE802.3at/af Power over Ethernet Switch Back-plane (Switching Fabric): 11.2Gbps Architecture Packet throughput ability (Full-Duplex): 23.8Mpps @64bytes Transfer Rate 14,880pps for Ethernet port 148,800pps for Fast Ethernet port 1,488,000pps for Gigabit Fiber Ethernet port Marvell 800Mhz 256M Byte Flash...
Page 10
DI/DO 1 Digital Input (DI) : Level 0: -30~2V / Level 1: 10~30V Max. input current:8mA 1 Digital Output(DO): Open collector to 40 VDC, 200mA Operating 5% ~ 95% (Non-condensing) Humidity Operating -40°C~75°C / -40°F~167°F Temperature (72V model: -40°C~60°C / -40°F~140°F) Storage -40°C~85°C / -40°F~185°F Temperature...
Page 11
250mm(W)x179mm(H)x82mm(D) Weight 2.1kgs(IP67); 1.8kgs (IP43) Installation DIN Rail** and Wall Mount Design EMI & EMS FCC Class A, CE EN55022 Class A, CE EN55024, CE EN61000-4-2, CE EN61000-4-3, CE EN61000-4-4, CE EN61000-4-5, CE EN61000-4-6, CE N61000-4-8, EN61000-4-11 Stability Testing IEC60068-2-32 (Free fall), EN61373 (Shock and Vibration) MTBF 217,019 hrs Verifications&...
Page 12
148,800pps for Fast Ethernet port 1,488,000pps for Gigabit Fiber Ethernet port Marvell 800Mhz 256M Byte Flash 128M Byte Mac Address 16K MAC address table Jumbo frame 10KB on all ports Connectors 10/100TX: 16 x ports M12 4-pole D-coded with Auto MDI/MDI- X function 10/100/1000T: 4 x ports M12 8-pole A-coded with Auto –X...
Page 13
Temperature (72V model: -40°C~60°C / -40°F~140°F) Storage -40°C~85°C / -40°F~185°F Temperature Power Supply Standard model: 33.6~60VDC dual input 24V model: 16.8~33VDC dual input 72V model: 50.4~90VDC dual input 110V model: 43~137.5VDC dual input PoE Budget 480W for 45~56V input (55V input is recommended for 802.3at 30W applications) 120W for 24V input 120W for 72V Input 90W for 110V Input...
Page 14
Stability Testing IEC60068-2-32 (Free fall), EN61373 (Shock and Vibration) MTBF 203,334 hrs Verifications& EN50155/EN50121-3-2/EN50121-4 verification report EN45545-2 R24 (EN ISO 4589-2, EN ISO 5659-2, NF X70- 100-1 & 2) Fire & Smoke verification Warranty 5 years *Future release **Optional...
Chapter 2 Hardware Description In this paragraph, it will describe the Industrial switch’s hardware spec, port, cabling information, and wiring installation. 2.1 Physical Dimension Aluminum case. IP-67, 285 (W) x 201.4 (D) x 84.4 (H) mm Port description of IP-67 series switch...
Aluminum case. IP-43, 273 (W) x 188.4(D) x 84.4 (H) mm **The port description of IP-54/IP-43 model is the same as of IP-67 one. 2.2 Package Content: Manual CD Product Console cable...
2.3 IP Protection The IP Code, Ingress Protection Rating, sometimes also interpreted as International Protection Rating, classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water in mechanical casings and with electrical enclosures. It is published by the International Electrotechnical Commission (IEC) Solid particle protection The first digit indicates the level of protection that the enclosure provides against access...
Page 19
Liquid ingress protection The second digit indicates the level of protection that the enclosure provides against harmful ingress of water. Protected Level Testing for Details against — — protected Dripping Dripping water (vertically Test duration: 10 minutes water falling drops) shall have no Water equivalent to 1 mm harmful effect.
Page 20
Powerful Water projected in powerful Test duration: at least water jets jets (12.5 mm nozzle) 3 minutes against the enclosure from Water volume: 100 litres per any direction shall have no minute harmful effects. Pressure: 100 kPa at distance of 3 m Immersion Ingress of water in harmful Test duration: 30 minutes...
2.4 LED Indicators The diagnostic LEDs that provide real-time information of system and optional status are located on the front panel of the industrial switch. The following table provides the description of the LED status and their meanings for the switch. Color Status Meaning...
Page 22
The port is transmitting or receiving packets Blinking from the TX device. No device attached.
Chapter 3 Hardware Installation 3.1Hardware installation 3.1.1Unpack switch and check the accessory with packing content list 3.1.2 Mount the switch on desired position. For the best ventilation, it is suggested to mount the switch on metallic surface. 3.1.3 Connect the M23/M12 connector of power input. The PoE power supply for IPES-5416T-8 series is connected via a 5-pole M23 female connector while IES-5416T is with a 5-pole M12 female connector.
Page 24
9.5V to 56VDC to feed power on both the 802.3af and 802.3at standardized devices. 24V model: The power input voltage can be from 16.8V to 33VDC to feed power on both the 802.3af and 802.3at standardized devices. 72V model: The power input voltage can be from 50.4V to 90VDC to feed power on both 802.3af/at standardized devices.
Page 25
Non-PoE model (M12) PoE model (M23) Pin assignment of Power input Dual Power Input The power input can be supported redundantly. The supply voltage is electrically isolated from the housing. Note: With single power supply of the mains voltage, the device will report a power failure.
Page 26
get exposed with dirt. Plug the connector to the power supply plug then turn on the power supply. Ground The chassis is grounded via a separate ground nut (M3). Use toothed locking washers for a good electrical connection. Ground screw of IPES-5408T switch 3.1.5 Connect the M12 connector with RJ-45 data cable, ports are not used shall be caped that comes with the package to insulate the surrounding.
Page 27
Pin assignment of M12 10/100Tx network connector Pin assignment of M12 10/100/100T network connector (non-X model)
Page 28
Pin assignment of M12 10/100/100T network connector (-X model) 3.1.6 Check the status of LED, make sure the switch was in working status. Note: The protection class IP67/IP43 is only achieved when bolted together. The other components attaching to the system have to meet with the IP67/IP43 protection class in order to reach the whole system IP 67/IP43 protection.
Chapter 4 Network Application 4.1 ITU G.8032 Scheme LANTECH G.8032 protocol is following ITU (International Telecommunication Unit) G.8032 v2 draft. The benefits of G.8032 are: 1. <50ms recovery time when failover 2. G.8032 has defined the protocol scheme, parameters, functions, test measures to be unified that the users can evaluate the possible network infrastructure without literally testing each brand in large scale.
Chapter 5 Console Management 5.1 Connecting to the Console Port The supplied cable which one end is M12 5-pole connector and the other end is RS-232 connector. Attach the end of RS-232 connector to PC or terminal and the other end of M12 connector to the console port of the switch.
Page 34
The settings of communication parameters Having finished the parameter settings, click ‘OK’. When the blank screen shows up, press Enter key to have the login prompt appears. Key in ‘admin’ (default value) for both User name and Password (use Enter key to switch), then press Enter and the Main Menu of console management appears.