Optional Accessories - Nice Era Fit S Instructions And Warnings For Installation And Use

Tubular motor
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
6

OPTIONAL ACCESSORIES

6.1 - Climate sensors for wind, sun, rain
(only models with radio connection to motor)
The climatic sensors of the NEMO and VOLO series (models with radio only) control
the awning (or shutter) automatically in response to the weather conditions. Caution
– The "sun" and "wind" threshold can only be adjusted on the climatic sensor itself.
Refer to the sensor manual.
6.1.1 - Definitions and conventions
• Manual "Sun On" command = enables the reception, by the motor, of automatic
commands transmitted by the "Sun" sensor if present in the installation. When re-
ception is enabled, the user can send manual commands at any time: these over-
write the automatic operation of the automation.
• Manual "Sun Off" command = enables the reception, by the motor, of automatic
commands transmitted by the "Sun" sensor if present in the installation. When the
reception is disabled, the automation operates exclusively with the manual com-
mands sent by the user. The "Wind" and "Rain" sensors cannot be disabled be-
cause they protect the automation from the action of wind and rain.
• "Over-threshold" intensity of sun/wind = a condition in which the atmospheric
phenomenon stands at values that are above the value set as threshold.
• "Under-threshold" Intensity of sun/wind = a condition in which the atmos-
pheric phenomenon stands at values ranging from zero to half of the value set as
threshold.
• "Wind protection" = a condition in which the system inhibits all the awning/shut-
ter opening commands because of the over threshold wind intensity.
• "Presence of rain" = a condition in which the system detects the presence of
rain, with respect to the previous condition of "absence of rain".
• "Manual command" = Raise, Lower or Stop command sent by the user by
means of a transmitter.
6.1.2 - Behaviour of the motor in the presence of climate
sensors
6.1.2.1 - Behaviour of the motor in the presence of "Sun" sensor (fig. 7)
When the intensity of the sunlight reaches the over-threshold, after 2 minutes from
the beginning of this condition the motor autonomously performs a lowering ma-
noeuvre. When the intensity of the sunlight reaches the under-threshold, after 15
minutes from the beginning of this condition the motor autonomously performs a
raise manoeuvre. Note – Momentary drops in solar intensity, lasting less than 15
minutes, are not detected. The manual commands of the user always remain active
and are added to those generated automatically by the system.
6.1.2.2 - Behaviour of the motor in the presence of "Rain" sensor (fig. 8)
The rain sensor recognised 2 states: "absence of rain" and "presence of rain".
When the motor receives the "presence of rain" information, it activates the com-
mand programmed in the same motor for this state (e.g., closing of the awning/
shutter). The rain sensor is deactivated after the absence of rain has been detect-
ed for at least 15 minutes.
The manual commands of the user always remain active and are added to those
generated automatically by the system. Therefore, in case a manual command is
sent that is contrary to the previous automatic command, the system carries out the
manoeuvre and starts, in that same moment, a 15 minute timer that regenerates the
programmed automatic command once this time elapses (e.g., the closure of the
awning/shutter).
Example: 1. The awning/shutter is open. 2. It starts raining... 3. The awning/shut-
ter is automatically closed by the system. 4. After a few minutes (it continues rain-
ing...) the user commands the opening of the awning/shutter. 5. After 15 minutes
from the opening (it continues raining...) the awning/shutter is closed automatically
by the system. 6. It stops raining. 7. It does not rain for at least 15 minutes: the user
commands the awning/shutter to open again. 8. The awning/shutter remains open.
6.1.2.3 - Behaviour of the motor in the presence of "Wind" sensor (fig. 9)
When the intensity of the wind reaches the over-threshold, the system activates the
wind protection and automatically closes the awning/shutter. With the wind protec-
tion inserted the manual commands are deactivated and it is not possible to open
the awning/shutter. At the end of the barring period the manual commands are reac-
tivated and after 15 minutes the automatic operation is restored.
6.1.2.4 - Priority among atmospheric events and operating priority among
the "Sun", "Rain" and "Wind" sensors
The priority scale among the atmospheric events is as follows: 1) - wind, 2) - rain, 3)
- sun. Wind has a higher priority than the others. A phenomenon with a higher prior-
ity resets the phenomenon underway, if this has a lower priority.
Example:
1. On a sunny day, the intensity of the light is over-threshold; the sensor makes the
awning/shutter open automatically.
2. Rain hits the sensor; the system resets the existing sun condition and commands
the manoeuvre envisaged for the new rain condition.
3. The intensity of the wind increases and reaches the over-threshold; the motor
deactivates the automatic sequence set for the rain and commands a raise ma-
noeuvre (the awning/shutter will be locked by the system in the "0" closing posi-
tion as long as the intensity of the wind remains over-threshold).
4. The wind dies down and reaches the wind under-threshold; after about 10 min-
utes the wind alarm condition stops; at this point, if there is still the "raining" con-
dition, the rain sensor is reactivated and the preset manoeuvre is commanded.
5. When the sensor detects the "not raining" condition, it reactivates the "sun" sensor
and, if the light intensity is over-threshold, the system opens the awning/shutter.
6. When the light intensity drops to the under-threshold, after about 15 minutes a
raise manoeuvre is commanded.
6.1.2.5 - "Sun-On" and "Sun-Off" commands sent by the user
The user may activate ("Sun-On" ) or deactivate ("Sun-Off" command) the reception
by the motor of automatic commands transmitted by the climate sensors present in
the installation. If at the time when the "Sun-On" command is sent the sunlight inten-
sity is over-threshold, the system commands the opening of the awning/shutter; in-
stead, if in that moment the sensor is already activated, the system is reset and acti-
vates the sensor again, making the algorithms start again immediately.
If no manoeuvre is set when the "Sun-On" command is sent, the motor signals the
reception of the command by performing 2 movements. If at that time the sunlight
intensity is under-threshold and does not allow the awning/shutter to be opened,
the motor will command the closure of the awning/shutter, in accordance with this
condition. In the conditions to perform a manoeuvre are not met (e.g. because the
awning/shutter is closed and it is not sunny), the motor will perform 2 movements to
signal the reception of the command, upon receiving the "Sun-On" command. By
sending the "Sun-Off" command, the automatic movement of the awning/shutter is
inhibited in connection with the sun phenomenon. Therefore the automation will only
work in the manual mode. Warning – The "wind" and "rain" sensors cannot be de-
activated.
English – 12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Era fit seriesEra fit mEra fit l

Table of Contents