In North America
The outside unit's terminal block is protected by
an electrical wiring cover on the side of the unit.
A comprehensive wiring diagram is sticked on
the inside of the wiring cover.
Remove the wire cover from the unit by
loosening the 3 screws.
Dismount caps on the conduit panel.
Temperarily mount the conduit tubes(not
included) on the conduit panel.
Properly connect both the power supply and
low voltage lines to the corresponding
terminals on the terminal block.
Ground the unit in accordance with local codes.
Be sure to size each wire allowing several inches
longer than the required length for wiring.
Use lock nuts to secure the conduit tubes.
NOTE: Please choose the right cable size
according to the Minimum Circuit Ampacity
indicated on the nameplate of the unit.
How to properly connect the wire lines.
Loop
Insulation
Solid wire
Step 1:
The treatment about the end of the wire.
Wall receptacle or
Air break switch(North America)
(purchased seperately)
Outdoor unit power wires
Outdoor unit
(A)
Round
terminal
Strand wire
Indoor & Outdoor
connective wires
(purchased seperately)
Indoor unit
Terminal block
Wire Cover
Please select the appropriate through-hole according
to the diameter of the wire.
Screw with
special
washer
Round terminal
Terminal plate
Wire
Step 2:
connecting the line to the corresponding terminals
on the terminal block.
Indoor unit power wires
Outdoor unit
Indoor & Outdoor
connective wires
(purchased seperately)
24
Connecting cable
G G
Power supply cord
Conduit panel
Screw with
special
washer
Round
terminal
Wire
Wall receptacle or
Air break switch
(North America)
(purchased seperately)
Indoor unit
(B)