Midea MFEP26VA-N User Manual page 13

Table of Contents

Advertisement

2
Drill wall hole for connective piping
Determine wall hole location
NOTE : The wall hole size
The size of the wall hole is determined by the connective pipes. When the size of the gas side
connective pipe is
connective pipe is less than
Step 1:
Remove the screw that attaches the
mounting plate to the back of the
indoor unit.
Step 2:
Secure the mounting plate to the wall
with the screws provided. Make sure
that mounting plate is flat against
the wall.
Correct orientation of Mounting Plate
Step 3:
Confirm the mounting plate you own.
Determine the location of the wall hole based
on the position of the mounting plate. The
dotted rectangular box on the right figure
shows the size of your product.
CAUTION: For the convenience of installation,
there are bubble level, carved dimensions on
the mounting plate.The Bubble level on the
mounting plate can't be removed. If it is broken,
make sure to clean up the leaking liquid.
Φ
16mm(5/8") or more, the wall hole should be 90mm(3-9/16"). For the size of
Φ
16mm(5/8"), the wall hole should be 65mm(2-1/2").
Unit: mm(inch)
Horizontal direction ruler
mm
100
100
50
50
4
inch
2
2
LIQUID
GAS
BUBBLE
LEVEL
pipe hole
65(2.5)
Φ
50(1.9)
Indoor unit dimensions(WxH):
795mm(31in)x295mm(11.6in)
pipe hole
65(2.5)
Φ
50(1.9)
Indoor unit dimensions(WxH):
965mm(38in)x322mm(12.7in)
50(1.9)
pipe hole
Φ
90(3.54)
Indoor unit dimensions(WxH):
1140mm(44.8in)x370mm(14.6in)
11
50
2
4
100
Vertical direction
4
ruler
mm
inch
150
6
RECOMMAND
425(16.7)
120(4.7)
490(19.3)
570.7(22.5)
pipe hole
65(2.5)
Φ
pipe hole
65(2.5)
Φ
95(3.7)
70(2.8)
pipe hole
Φ
90(3.54)

Advertisement