The outdoor unit can be anchored to the ground or to a wall-mounted bracket with bolt(M10). Prepare
the installation base of the unit according to the dimensions below.
The following is a list of di erent outdoor unit sizes and the distance between their mounting feet.
Prepare the installation base of the unit according to the dimensions below.
Air inlet
Outdoor Unit Dimensions (mm)
668x469x252 (26.3"x 18.5"x 9.9")
680x542x248 (26.8"x 21.3"x 9.8")
700x550x275 (27.5"x 21.6"x 10.8")
720x495x270 (28.3"x 19.5"x 10.6")
765x555x303 (30.1"x 21.8"x 11.9")
770x555x300 (30.3"x21.8"x11.8")
800x554x333 (31.5"x21.8"x13.1")
805x554x330 (31.7"x 21.8"x 12.9")
845x702x363 (33.3"x 27.6"x 14.3")
890x673x342 (35.0"x 26.5"x 13.5")
946x810x420 (37.2"x 31.9"x 16.5")
946x810x410 (37.2"x 31.9"x 16.1")
If you will install the unit on the
ground or on a concrete mounting
platform, do the following:
Mark the positions for four expansion bolts
based on dimensions chart.
Pre-drill holes for expansion bolts.
Place a nut on the end of each expansion bolt.
Hammer expansion bolts into the pre-drilled
holes.
Remove the nuts from expansion bolts, and
place outdoor unit on bolts.
Put washer on each expansion bolt, the
replace the nuts.
Using a wrench, tighten each nut until snug.
CAUTION
Make sure that the wall is made of solid brick, concrete, or of similarly strong material.
The wall must be able to support at least four times the weight of the unit.
A
Air inlet
Air outlet
Top view
W x H x D
W
Front view
Mounting Dimensions
Distance A (mm)
430 (16.9")
452 (17.8")
450 (17.7")
452 (17.8")
452 (17.8")
487 (19.2")
514 (20.2")
511 (20.1")
540 (21.3")
663 (26.1")
673 (26.5")
673 (26.5")
If you will install the unit on a wall-mounted
bracket , do the following:
Mark the position of bracket holes based on dimensions
chart.
Pre-drill the holes for the expansion bolts.
Place a washer and nut on the end of each expansion bolt.
Thread expansion bolts through holes in mounting
brackets, put mounting brackets in position, and hammer
expansion bolts into the wall.
Check that the mounting brackets are level.
Carefully lift unit and place its mounting feet on brackets.
Bolt the unit firmly to the brackets.
If allowed, install the unit with rubber gaskets to reduce
vibrations and noise.
22
H
Distance B (mm)
231 (9.1")
230 (9.1")
260 (10.2")
255 (10.0")
286(11.3")
298 (11.7")
340 (13.4")
317 (12.5")
350 (13.8")
354 (13.9")