ENTANGLEMENT HAZARD
• Do not operate with access door open.
• Do not place hands or fingers near
rotating or moving parts.
• Do not operate without guard.
• Stop engine and remove key, before
working on the machine.
Do not operate the conveyor when:
• It is plugged with excess seed
• Hindered from moving by a foreign object.
Continued operation can cause damage to
conveyor or result in a broken conveyor belt.
If the conveyor tube becomes plugged:
1. Position the conveyor for easy access to
both ends.
2. Stop the engine and remove the ignition key.
3. Lock-Out, Tag-Out the tender control panel
inside the box.
4. Open the lower access door at the base of
the conveyor.
5. Remove the spout to gain access if needed.
6. Clean out seed and remove any obstruction.
7. Close and secure the access door.
- Reattach the spout.
Note:
In some extreme case it may be
necessary to remove the galvanized
belt guards and/or the belt itself.
11.2022
Bulk Seed Tender
®

3.11 UNPLUGGING

Fig 41 - Conveyor tube access door
®