Unplugging - Meridian SEED EXPRESS Bulk Seed Tender Operator's Manual

Table of Contents

Advertisement

Operator's Manual: 240 FF Basic Seed Express
ENTANGLEMENT HAZARD
• Do not operate with access door open.
• Do not place hands or fingers near
rotating or moving parts.
• Do not operate without guard.
• Stop engine and remove key, before
working on the machine.
Do not operate the conveyor when:
• It is plugged with excess seed
• Hindered from moving by a foreign object.
Continued operation can cause damage to
conveyor or result in a broken conveyor belt.
If the conveyor tube becomes plugged:
1. Position the conveyor for easy access to
both ends.
2. Stop the engine.
3. Remove the ignition key for safety.
4. Open the lower access door at the base of
the conveyor.
5. Remove the spout to gain access if needed.
6. Clean
out
product
obstruction.
7. Close and secure the access door.
- Reattach the spout.
Note:
In some extreme case it may be
necessary to remove the galvanized
belt guards and/or the belt itself.
Revised 01.2022

3.9 UNPLUGGING

and
remove
any
Bulk Seed Tender
®
Fig 36 - Conveyor tube access door
®
3-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

240 ff