External interrupt and clock cable diagnostic reference
Hide thumbs Also See for StorEdge A7000:
Table of Contents

Advertisement

Enter one of the following or a standard response:
Response
Description
Enables displaying debug messages during diagnostic execution.
Y
Inhibits displaying debug messages during diagnostic execution.
N
4. The program displays:
Do you wish to enable scope loops? = No ;[cr,?,^,Y,N]?
Enter one of the following or a standard response:
Response
Description
Enables scope loops.
Y
Inhibits scope loops.
N
Scope loops are useful for troubleshooting a specific cable connection. If scope
loops are enabled, all messages except the test starting milestone message are
disabled.
Note – After running the diagnostic with scope loops enabled, you must enter
Control-C to exit the scope loops and return to the ROM>> prompt.
When using scope loops, enable only the interrupt or clock to which the scope is
attached and use the interactive mode t option to select the test related to the cable
connection under observation (Test 1 for an interrupt or Test 2 for a clock).
5. The program displays:
Do you wish to check for all external
interrupt cables? = Yes ;[cr,?,^,Y,N]?
Enter one of the following or a standard response:
Response
Description
Enables testing all external interrupt cables.
Y
Enables testing a single external interrupt cable.
N
Chapter 2
Program Initialization
2-3