Configure your device
This example explains how to direct the camera and open a gate when someone wants to enter during daytime. This is done by
connecting a PIR detector to the product's input port and a switch relay to the product's output port.
Required hardware
Multicable (sold separately), see Multiconnector on page 64.
Mounted PIR detector
Switch relay connected to the gate lock, in this case the switch is normally closed (NC)
Connecting wires
Physical connection
1. Remove the plug from the camera's multi-connector and connect the multicable.
2. Connect the wires from the PIR detector to the input pin, see Multiconnector on page 64.
3. Connect the wires from the switch to the output pin, see Multiconnector on page 64.
1. Connect the wires from the PIR detector to the input pin, see .
2. Connect the wires from the switch to the output pin, see
Configure I/O ports
You need to connect the switch relay to the camera from the camera's web interface. First, configure the I/O ports:
Set the PIR detector to an input port
1. Go to System > Accessories > I/O ports.
2. Click
3. Give the input module a descriptive name, for example "PIR detector".
4.
If you want to trigger an event whenever the PIR detector senses motion, click
Set the switch relay to an output port
1. Click
2. Give the output module a descriptive name, for example "Gate switch".
3.
If you want to open the gate whenever an event is triggered, click
Create rules
For the camera to open the gate when the PIR detector senses someone nearby, you need to create a rule in the camera:
1. Go to System > Events and add a rule.
2. Type a name for the rule, for example "Open gate".
3. In the list of conditions, select PIR detector.
4. In the list of actions, select Toggle I/O once.
5. In the list of ports, select Gate switch.
to set the direction to input for port 1.
to set the direction to output for port 2.
to set the normal state to circuit closed.