Orifice Cleaning:
Clogged orifices create a dangerous condition that
must be resolved before the grill may be used. If
you are not entirely comfortable with the procedure,
please use a qualified technician or contact
Kalamazoo Outdoor Gourmet customer service at
+1.800.868.1699.
To clean and inspect the main burner orifices, remove
the control panel according to the instructions
beginning on page 44. Remove the main burners
according to the instructions on page 59. Use a 1/2"
wrench to carefully thread the orifices (Figure 24:A)
off the valve bodies (Figure 24:B). Shine a flashlight
through the orifice to look for any obstructions.
Remove obstructions with a needle. Use extreme
care not to enlarge the hole. Reinstall and tighten
the orifice. Reinstall the burners according to the
instructions on page 59. Test fire the burners and
check for proper flame characteristics.