hold & serve drawer
COMPUTER DISPLAY
STEP 7
STEP 8
STEP 9
TO SET DIFFERENT HOLDING TIMES for
each of the other 7 channels, repeat steps 2
and 3, then skip to step 8.
OTHER PROGRAMMING FEATURES
REBOOT PROCEDURE
On rare occasions, a power interruption may
occur, making it necessary to reboot the
controller software. To reboot, leave power
cord on, and unplug drawer from power
receptacle. Press and hold the #8 channel
key while plugging the unit back in. Drawer
will reboot to original factory settings.
NOTE: If location experiences frequent
power interruptions, use of a surge protector
is recommended.
10
PRESS KEY/ACTION
or
1
CHANGING FROM FAHRENHEIT TO
CELSIUS
Press and hold the #9 key (hidden - located
directly beneath the #1 key (see illustration
below)) while turning on the power switch.
Repeat to switch from CELSIUS back to
Fahrenheit. LED display will indicate which
temperature scale is currently active.
Key 9
(hidden)
www.winstonind.com • 800-234-5286
NOTES
Use arrow keys to adjust the
Food Texture setting. Hold
either key down for fast
scrolling (0 to 210˚F (32 to
99ºC)). 300˚F (149ºC)
maximum when added to
Food Temp setting.
To exit programming, press
and hold the #1 channel key
for 3 seconds until the
software ID# and JF00
appear. The cabinet will then
start heating to the set
temperature.
Programming is complete.