Discharge of flue gases
Gas cooking appliances must discharge their flue gases through hoods
connected directly to flues or the outdoors. If it is not possible to install the
hood (fig. B) an electric fan must be installed on the outside wall or the window
of the room, provided it is possible for the ventilation opening to be increased
in proportion to the delivery rate of the fan (fig. C).
For a kitchen, the delivery rate of this electric fan must guarantee an hourly air
exchange of 3-5 times its volume. In both instances, the use of flues already
used by other appliances to discharge the flue gases is forbidden.
When the installation is complete, always check that all the joints are
absolutely tight using a soapy solution. Never use a flame to make
this check.

MAIN SPECIFICATION

EGH-F9542G(GR)
Gas Source
: LPG
Rated Gas Pressure: 2,800 (Pa)
Burner Rating : 5.0kW (Left), 5.0kW (Right)
Product Dimension (mm): 860 (W) x 500 (D) x 165 (H)
Built-in Dimension (mm): 750 (W) x 470 (D)
EGH-F9543G(GR)
Gas Source
: LPG
Rated Gas Pressure: 2,800 (Pa)
Burner Rating : 5.0kW (Left), 5.0kW (Right), 1.75kW (Middle)
Product Dimension (mm): 860 (W) x 500 (D) x 165 (H)
Built-in Dimension (mm): 750 (W) x 470 (D)