INSTRUCTIONS FOR THE INSTALLATION TECHNICIAN

CAUTION: This appliance must only be installed and used in rooms
with permanent ventilation to local standards.
Installation of the appliance and its connection to the gas supplies must only
be carried out by qualified technician. Before any procedure, it is important to
check that the appliance is DISCONNECTED from the gas supplies. The
Manufacturer declines all responsibility for any damage arising from
installation in breach of the regulations in force or from failure to comply with
the accident prevention regulations.

INSTALLATION PREMISES

For proper operation of a gas appliance, the air
necessary for the combustion of the gas must be able
to flow into the room naturally. The air must flow into
the room directly through openings in the outside walls.
These
openings
cross-section not less than 2m
power (see total power in kw on the appliance rating
label).
This opening must be constructed so that it will not be
obstructed from inside or outside, or constructed close
to the floor. The opening is recommended to be on the
side opposite to that on which the flue gases are
discharged. If it is not feasible to provide these
openings in the room where the appliance is installed,
the necessary air may be taken from an adjacent
room, provided that:
-
this room is not a bedroom or a hazardous
environment;
-
this room has ventilation;
-
the ventilation between the room where the
appliance is installed and the adjacent room has
openings.
must
have
an
3
/h for each kw of
unobstructed
6