Part Replacement Procedures
18. Tighten the tray bolts, using the same star pattern shown in
torque driver shaft with the index finger, middle finger, and thumb.
Tighten the bolts until they are finger-tight.
19. When all eight bolts are finger-tight, use the 4-Nm torque driver, in the same star pattern, to
torque all bolts to 6 Nm.
20. Repeat tightening all bolts to 6 Nm in a circular pattern two times.
Part Replacement Procedures
Replacing the Resin Ingress Tube
Required Tools
Nitrile gloves
Wire cutters
Nylon tube
Tube plugs
Two zip ties
4-mm hex driver
T10 Torx driver
Procedure
1. Open the printer door and remove the resin tray, if installed.
2. With the door open, power down and unplug the printer.
3. Using a T10 Torx driver, remove the two fasteners securing the access panel on the left
side of the printer.
Figure 17: Finger tighten tray bolts
© Copyright 2022-2023 Stratasys. All rights reserved.
Replacing the Resin Ingress Tube
Figure
16, by holding the