7.3

Status Details

This section describes the STATUS field for main commands and the SUBSTATUS field for
sub-commands.
STATUS Field
Bit
Name
0
ALM
Alarm status
1
WARNG
Warning status
2
CMDRDY
Command ready
3
BB OFF
Baseblock OFF (OFF when output voltage is being
output from the Inverter or during baseblock.)
4
PON
Main power supply ON (OFF during undervoltage)
5
RUNX
Running
6
0SP
Zero speed
7
REV
Reverse RUN
8
RESET
Fault reset signal input
9
AGREE
Speed agreement
A
INV_READY
Inverter ready
B
OPE
OPE fault
C
UV_R
Recovery after power loss or recovery after momen-
tary power loss
D
REMOTE
Local or Remote
E
Not used.
F
Not used.
* With the MEM_RD command, only the settings for the STATUS (CMDRDY) is valid. Other
bits are not used.
Description
42
Value
Setting
0
No alarm
1
Alarm (fault)
0
No warning
1
Warning
0
Busy
1
Ready
0
Baseblock ON
1
Baseblock OFF
0
Main power supply OFF
1
Main power supply ON
0
1
Running
0
1
Zero speed
0
Forward RUN
1
Reverse RUN
0
1
Fault reset signal input
0
1
Speed agreement
0
1
Inverter ready
0
1
OPE fault
0
Recovery after power loss
1
Recovery after momentary
power loss
0
Local
1
Remote (Transfer)
0
1
0
1