Led Indicators - YASKAWA VS mini V7 User Manual

Mechatrolink communications interface unit
Hide thumbs Also See for VS mini V7:
Table of Contents

Advertisement

3.3

LED Indicators

The LED indicators indicate the status of the communications of the MECHATROLINK-I
or MECHATROLINK-II and the SI-T/V7 Unit.
However, these indicates are for maintenance checks at Yaskawa. Use the Digital Operator
to check the status.
Name
RUN
ERR
TX
RX
RUN
TX
Display
Color
Status
Green
Lit
Normal operation
Not lit
Communications CPU stopped, resetting hardware, RAM check
error, DPRAM check error, station address setting error, or
Inverter model code error
Red
Lit
Watchdog timeout error, communications error, or resetting hard-
ware
Red
Blinking
ROM check error (once)*, RAM check error (twice)*, DPRAM
check error (3 times)*, communications ASIC self-diagnosis error
(4 times) *, ASIC RAM check error (5 times)*, station address set-
ting error (6 times) *, Inverter model code error (7 times) *
*: Indicates the number of blinking.
Not lit
No communications error or self-diagnosis error
Green
Lit
Sending data
Not lit
Sending of dara stopped, hardware reset
Green
Lit
Searching for receiving carrier
Not lit
No receiving carrier found, resetting hardware