Station-number Setting
A station number is set by both the S1-3 DIP switch and the S2 rotary switch. Station num-
bers from 21 to 3E are valid. Although 20 or 3F can be set as a station number, do not use
these settings because they will be faulty.
S1-3: Set the 10's digit of the station number.
OFF = 2 (2X)
ON = 3 (3X)
S2: Set the 1's digit of the station number.
0 = 0 (X0)
1 = 1 (X1)
 
 
F = F (XF)
Switch Setting and Station Number
SI-3
S2
OFF
0
OFF
1
OFF
2
OFF
3
OFF
4
OFF
5
OFF
6
OFF
7
OFF
8
OFF
9
OFF
A
OFF
B
OFF
C
OFF
D
OFF
E
OFF
F
Station
S1-3
Number
Fault
ON
21
ON
22
ON
23
ON
24
ON
25
ON
26
ON
27
ON
28
ON
29
ON
2A
ON
2B
ON
2C
ON
2D
ON
2E
ON
2F
ON
14
S2
Station
Number
0
30
1
31
2
32
3
33
4
34
5
35
6
36
7
37
8
38
9
39
A
3A
B
3B
C
3C
D
3D
E
3E
F