Display Elements; Electrical Connection - Pepperl+Fuchs VOC M-F256-B12-V1D-CR0 Series Manual

Industrial event camera
Table of Contents

Advertisement

Industrial Event Camera
Product Specifications
2.4

Display Elements

Two LEDs on the front of the camera indicate the operating status.
Description of the LEDs
LED
Power
Status
2.5

Electrical Connection

The following connections are located on the sensor.
Connection Assignment
Note
Current Consumption
The maximum input current of the camera is 200 mA over the entire input voltage range with
the heater deactivated. When the heater is activated, the maximum input current is 700 mA.
14
Color
Meaning
Green
Illuminates when the camera is switched on
Blue
Illuminates blue from the trigger to the end of the recording
Yellow
Lights up yellow a few seconds after the system is switched on. The LED
turns off when the camera has been successfully initialized and is ready
for operation.
A software restart is also indicated via the yellow status LED.
Power supply and digital input connection
M12 plug, A-coded, 4-pin
Ethernet interface 10/100 Mbit
M12 socket, D-coded, 4-pin
4
1. Power supply + (18 V DC ... 28 V DC)
1
2. Digital input
Low: 0 % ... 5 V DC
High: 16 V DC ... 32 V DC
2
4
3. Power supply - (0 V)
4. Not used
3
1. TX+ Ethernet
1
2. RX+ Ethernet
3. TX- Ethernet
2
4. TX- Ethernet
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Voc5m-f256-b12-v1d-cr02Voc10m-f256-b12-v1d-cr03

Table of Contents