Exterior Vent Termination Locations (Non Power Vent) - Regency City CV50E DIRECT VENT Owners & Installation Manual

Table of Contents

Advertisement

Exterior Vent Termination Locations (Non Power Vent)

Minimum Clearance Requirements
A
Clearance above grade, veranda, porch, deck, or balcony
B
Clearance to window or door that may be opened
C
Clearance to permanently closed window
D
Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm)
from the center line of the terminal (check with the local code)
E
Clearance to unventilated soffit
F
Clearance to outside corner: with AstroCap Termination Cap.
Clearance to outside corner: with all other approved Termination Caps.
G
Clearance to inside corner: with AstroCap Termination Cap
Clearance to inside corner: with all other approved Termination Caps.
H
Clearance to each side of center line extended above meter/regulator assembly
J
Clearance to service regulator vent outlet
K
Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance
L
Clearance to a mechanical air supply inlet
#3' (91cm) above if within 10' (3m) horizontally.
M
Clearance above paved sidewalk or a paved driveway located on public property
N
Clearance under veranda, porch, deck, or balcony
1 In accordance with current CSA B149.1, Natural Gas and Propane Installation Code
2 In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code
┼ A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor
* Clearance in accordance with local installation codes and the requirements of the gas supplier
a 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly
b 3 feet (91cm) above - if within 10 feet (3m) horizontally
installation
1
2
Canada
USA
12"(30cm)
12"(30cm)
12"(30cm)
9" (23cm)
*
*
29"(74cm)
29"(74cm)
29"(74cm)
29"(74cm))
7"(18cm)
7"(18cm)
14"(36cm)
14"(36cm)
7"(18cm)
7"(18cm)
13"(33cm)
13"(33cm)
36"(90cm) a
*
36"(90cm)
*
12"(30cm)
9" (23cm)
36"(90cm) b
72"(1.8m)
84"(2.1m) ┼
*
12"(30cm) ‡
*
City Series CV50E |