Carrier CRDISKIT001A00 Installation Instructions Manual page 41

Variable frequency drive (vfd) remote keypad kit for 2-stage cooling units, 6-30 tons
Table of Contents

Advertisement

RGS072/089/090/100/102/119/120/150, RAS072/089/090/100/102/119/120/150, RHS090/102/120
RGH072/089/090/100/102/119/120/150, RAH072/089/090/100/102/119/120/150, RHH090/102/120
ACH550
VFD Part
Replacement
Replacement
Number
Component
Component
Part Number
Part Number
HK30WA364
HK30WA302
HK30WB358
HK30WA356
HK30WA318
HK30WB364
HK30WA366
HK30WA332
HK30WB368
HK30WA352
HK30WA303
HK30WB359
HK30WA356
HK30WA318
HK30WB364
HK30WA360
HK30WA333
HK30WB369
HK30WA352
HK30WA303
HK30WB359
HK30WA356
HK30WA318
HK30WB364
HK30WA353
HK30WA304
HK30WB360
HK30WA357
HK30WA319
HK30WB365
HK30WA361
HK30WA334
HK30WB370
HK30WA354
HK30WA305
HK30WB361
HK30WA358
HK30WA320
HK30WB366
HK30WA362
HK30WA335
HK30WB371
RGS072/089/090/100/102/119/120/150, RAS072/089/090/100/102/119/120/150, RHS090/102/120
RGH072/089/090/100/102/119/120/150, RAH072/089/090/100/102/119/120/150, RHH090/102/120
ACH550
VFD Part
Replacement
Replacement
Number
Component
Component
Part Number
Part Number
HK30WA364
HK30WA302
HK30WB358
HK30WA356
HK30WA318
HK30WB364
HK30WA366
HK30WA332
HK30WB368
HK30WA352
HK30WA303
HK30WB359
HK30WA356
HK30WA318
HK30WB364
HK30WA360
HK30WA333
HK30WB369
HK30WA352
HK30WA303
HK30WB359
HK30WA356
HK30WA318
HK30WB364
HK30WA353
HK30WA304
HK30WB360
HK30WA357
HK30WA319
HK30WB365
HK30WA361
HK30WA334
HK30WB370
HK30WA354
HK30WA305
HK30WB361
HK30WA358
HK30WA320
HK30WB366
HK30WA362
HK30WA335
HK30WB371
APPENDIX A — VFD REMOTE KEYPAD PARAMETERS
Table A — ACH550/580VFD Parameters —
48/50TC 07-14, 50TCQ 07-12, 48/50HC 07-12 and 50HCQ 08-09
580J/558J*07-14, 548J*07-12, 581J/551J*07-12 and 549J*08-09
ACH580
Motor Part
Description
Number
1.7 HP 230V
HD56FR233
1.7 HP 460V
HD56FR463
1.7 HP 575V
HD56FR579
2.4 HP 230V
HD56FE653
2.4 HP 460V
HD56FE653
2.4 HP 575V
HD56FE577
2.9 HP 230V
HD58FE654
2.9 HP 460V
HD58FE654
3.7 HP 230V
HD60FE656
3.7 HP 460V
HD60FE656
3.7 HP 575V
HD58FE577
5.3 HP 230V
HD60FK658
5.3 HP 460V
HD60FK658
5.3 HP 575V
HD60FE576
Table A — ACH550/580VFD Parameters — (cont)
48/50TC 07-14, 50TCQ 07-12, 48/50HC 07-12 and 50HCQ 08-09
580J/558J*07-14, 548J*07-12, 581J/551J*07-12 and 549J*08-09
ACH580
Relay Out 3
Description
1403
10.3
FLT/ (14)
1.7 HP 230V
Fault
FLT/ (14)
1.7 HP 460V
Fault
FLT/ (14)
1.7 HP 575V
Fault
FLT/ (14)
2.4 HP 230V
Fault
FLT/ (14)
2.4 HP 460V
Fault
FLT/ (14)
2.4 HP 575V
Fault
FLT/ (14)
2.9 HP 230V
Fault
FLT/ (14)
2.9 HP 460V
Fault
FLT/ (14)
3.7 HP 230V
Fault
FLT/ (14)
3.7 HP 460V
Fault
FLT/ (14)
3.7 HP 575V
Fault
FLT/ (14)
5.3 HP 230V
Fault
FLT/ (14)
5.3 HP 460V
Fault
FLT/ (14)
5.3 HP 575V
Fault
Motor
Nom
Nom
Voltage
Nom
Amps
RPM
9905
Freq
9906
9908
99.07
9907
99.06
99.09
99.08
230
5.8
60 Hz
1725
460
2.9
60 Hz
1725
575
3.1
60 Hz
1725
230
7.9
60 Hz
1725
460
4
60 Hz
1725
575
3.4
60 Hz
1725
230
9.2
60 Hz
1725
460
4.6
60 Hz
1725
230
11.2
60 Hz
1725
460
5.6
60 Hz
1725
575
4.2
60 Hz
1725
230
13
60 Hz
1740
460
6.4
60 Hz
1740
575
5.4
60 Hz
1725
Max
Min
Max
Switch
Amps
Freq
Freq
Freq
2003
2007
2008
2606
30.17
30.13
30.14
97.01
6.7
0 Hz
60 Hz
4kHz
3.3
0 Hz
60 Hz
4kHz
3.6
0 Hz
60 Hz
4kHz
9.1
0 Hz
60 Hz
4kHz
4.6
0 Hz
60 Hz
4kHz
3.9
0 Hz
60 Hz
4kHz
10.6
0 Hz
60 Hz
4kHz
5.3
0 Hz
60 Hz
4kHz
12.9
0 Hz
60 Hz
4kHz
6.4
0 Hz
60 Hz
4kHz
4.8
0 Hz
60 Hz
4kHz
15.0
0 Hz
60 Hz
4kHz
7.4
0 Hz
60 Hz
4kHz
6.2
0 Hz
60 Hz
4kHz
41
Const
Const
Const
Nom
Speed
Speed
Speed
HP
Sel
1
2
9909
1201
1202
1203
99.10
22.22
28.26
28.27
1.7
DI 2,3
40 Hz
60 Hz
1.7
DI 2,3
40 Hz
60 Hz
1.7
DI 2,3
40 Hz
60 Hz
2.4
DI 2,3
40 Hz
60 Hz
2.4
DI 2,3
40 Hz
60 Hz
2.4
DI 2,3
40 Hz
60 Hz
2.9
DI 2,3
40 Hz
60 Hz
2.9
DI 2,3
40 Hz
60 Hz
3.7
DI 2,3
40 Hz
60 Hz
3.7
DI 2,3
40 Hz
60 Hz
3.7
DI 2,3
40 Hz
60 Hz
5.3
DI 2,3
40 Hz
60 Hz
5.3
DI 2,3
40 Hz
60 Hz
5.3
DI 2,3
40 Hz
60 Hz
Stop
Accel/
Start Fcn
Accel
Fcn
Decel
2101
2202
2102
2201
21.19
28.72
21.03
21.19
Auto
Ramp Not Sel / 0 30 sec 30 sec
Automatic
Auto
Ramp Not Sel / 0 30 sec 30 sec
Automatic
Auto
Ramp Not Sel / 0 30 sec 30 sec
Automatic
Auto
Ramp Not Sel / 0 30 sec 30 sec
Automatic
Auto
Ramp Not Sel / 0 30 sec 30 sec
Automatic
Auto
Ramp Not Sel / 0 30 sec 30 sec
Automatic
Auto
Ramp Not Sel / 0 30 sec 30 sec
Automatic
Auto
Ramp Not Sel / 0 30 sec 30 sec
Automatic
Auto
Ramp Not Sel / 0 30 sec 30 sec
Automatic
Auto
Ramp Not Sel / 0 30 sec 30 sec
Automatic
Auto
Ramp Not Sel / 0 30 sec 30 sec
Automatic
Auto
Ramp Not Sel / 0 30 sec 30 sec
Automatic
Auto
Ramp Not Sel / 0 30 sec 30 sec
Automatic
Auto
Ramp Not Sel / 0 30 sec 30 sec
Automatic
Const
Speed
3
1204
28.28
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
Decel
2203
28.73