Download Print this page
Smarteh Longo LPC-2.A03 User Manual

Smarteh Longo LPC-2.A03 User Manual

Analog output module

Advertisement

Quick Links

USER MANUAL
Longo programmable controller
LPC-2.A03
Analog Output module
Version 1
SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0)5 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si

Advertisement

loading
Need help?

Need help?

Do you have a question about the Longo LPC-2.A03 and is the answer not in the manual?

Questions and answers

Summary of Contents for Smarteh Longo LPC-2.A03

  • Page 1 USER MANUAL Longo programmable controller LPC-2.A03 Analog Output module Version 1 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0)5 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si...
  • Page 2 Longo programmable controller LPC-2.A03 Written by SMARTEH d.o.o. Copyright © 2010, SMARTEH d.o.o. User Manual Document Version: 001 April 14, 2010...
  • Page 3 24 months is valid from the date of sale to the end buyer, but not more than 36 months after delivery from Smarteh. In case of claims within warranty time, which are based on material malfunctions the producer offers free replacement. The method of return of malfunctioned module, together with description, can be arranged with our authorized representative.
  • Page 4 Longo programmable controller LPC-2.A03 Longo programmable controller LPC-2.A03 1 DESCRIPTION...................1 2 FEATURES..................2 3 INSTALLATION..................3 3.1 Connection scheme example............3 3.2 Mounting instructions..............5 3.3 Module labeling................6 4 TECHNICAL SPECIFICATIONS..............7 CHANGES ..................8 5 NOTES...................9...
  • Page 5 Longo programmable controller LPC-2.A03 1 DESCRIPTION LPC-2.A03 is two analog outputs module. Outputs can be individually set to work in current or voltage mode with correspondent jumper. In current output mode module generates 0 .. 20 mA, if configured as voltage output mode it generates 0 ..
  • Page 6 Longo programmable controller LPC-2.A03 2 FEATURES Figure 1: LPC-2.A03 analog module. Table 1: Technical data 2 analog outputs Voltage / current output range: 0 .. 10 V @ ±2 % / 0 .. 20 mA @ ±2 % accuracy of full scale value Output can be set as current or voltage type (jumper configurable) Standard DIN EN50022-35 rail mounting...
  • Page 7: Installation

    Longo programmable controller LPC-2.A03 3 INSTALLATION 3.1 Connection scheme example Figure 2: Connection scheme example...
  • Page 8 Longo programmable controller LPC-2.A03 Table 1: Outputs set as voltage set as current analog out 0 .. 10 V OUT1.1 (Q) analog out 0 .. 20 mA OUT1.2 (┴) analog out 0 .. 10 V OUT2.3 (Q) analog out 0 .. 20 mA OUT2.4 (┴) Table 2: K1 Internal BUS...
  • Page 9: Mounting Instructions

    Longo programmable controller LPC-2.A03 3.2 Mounting instructions Figure 3: Housing dimensions Dimensions in milimeters. All connections, module attachments and assembling must be done while module is not connected to the main power supply. Mounting instructions: 1. Switch OFF main power supply. 2.
  • Page 10: Module Labeling

    Label 2 description: 1. S/N:A03-S9-1000000190 is the serial number. A03 – short product name, • S9 – user code (test procedure, e.g. Smarteh person xxx), • 0500000190 – year and current stack code, • 05 – year (last two cyphers), •...
  • Page 11: Technical Specifications

    Longo programmable controller LPC-2.A03 4 TECHNICAL SPECIFICATIONS Table 5: Technical specifications Power supply from internal BUS Number of analog outputs Connection type screw type connector for stranded wire 0.75 to 2.5 mm Max. power consumption Max. current consumption 20 mA per output voltage mode current mode Analog output accuracy of the full...
  • Page 12 Longo programmable controller LPC-2.A03 CHANGES The following table describes all the changes to the document. Date Description 28.4.2010 The initial version, issued as LPC-2.A03 analog output module UserManual.
  • Page 13 Longo programmable controller LPC-2.A03 5 NOTES...