10.2.2
Personal protective equipment required
10.3
Daily maintenance
▪
Checking the water pipes for free flow
▪
Visual inspection of the 220µ pre-filters for contamination
▪
Control of the fine filters via pressure gauge
10.4
Filter change
The fine filters are monitored via the pressure gauge. We recommend changing the
filter at approx. 3bar.
Attention:
▪
Filter change only when the unit is switched off
▪
Remove dirty filters when damp to prevent the release of filter dust.
▪
Only use approved filters
▪
Damaged filter cartridges must not be used
Water management system C 400 V
Original operating instructions
Maintenance work, including changing / removing the filters, may
only be carried out by authorised persons wearing suitable
protective clothing.
Union nut
Pressure gauge Filter monitoring
Filter head spanner
Maintenance
30 from 40
Version 2