Instruction Manual Negative Pressure Unit green dec Table of contents 1. Basic safety advice ......................4 1.1. Intended use ............................ 5 1.2. Dangers ............................6 2. Transport and storage ....................... 7 2.1. Delivery ............................7 ...
Page 3
Instruction Manual Negative Pressure Unit green dec 7.3.9. Service ........................... 45 7.3.10. Software packages ........................ 46 7.3.11. Device information ......................... 47 7.3.12. Alarms ............................ 47 7.3.13. Turn off the device ......................... 49 8. ...
Instruction Manual Negative Pressure Unit green dec The copyright of this instruction manual remains with deconta. This manual is intended for assembly, operation and maintenance personnel. It contains instructions and drafts of technical nature which may neither be distributed nor used in any unauthorised way for competitive purposes or passed on to others.
The user is liable for any damages or injuries of any kind whatsoever. ATTENTION! The device was only tested with original deconta HEPA filters H13 and original deconta HEPA filters H14. To ensure machine safety, only original deconta filters should be used.
Touching a defective mains cable may result in death or serious injury. Do not damage the mains cable (e.g. by vehicle overrun, tearing, squeezing). Regularly check the mains cable for damage. Have defective mains cable replaced before use by the deconta service or a qualified electrician. CAUTION Damage due to unsuitable mains voltage.
Instruction Manual Negative Pressure Unit green dec 2. Transport and storage 2.1. Delivery The negative pressure unit is delivered on a pallet. To protect against weather influences and damage during transport, the device is wrapped in a plastic film. Transport damage must be immediately documented following delivery by the supplier. Please note any damages on the consignment note.
Instruction Manual Negative Pressure Unit green dec 3. Delivery contents Included in the delivery contents of a negative pressure unit, independent of whether a device has been purchased or rented, unless other agreements have been made: Negative Pressure Unit ...
EN 1822 class H13 4.2. Performance data G 100 110 V 230 V Air performance, free-blowing max. 2000 m³/h 2300 m³/h + deconta H13 or H14 filter 1500 m³/h 1800 m³/h max. + pre- and intermediate filter 1350 m³/h 1650 m³/h (EU3, EU4) max.
Negative Pressure Unit green dec 4.3. Performance data G 200 110 V 230 V Air performance, free-blowing max. 4000 m³/h 4500 m³/h + deconta H13 or H14 filter 3050 m³/h 3400 m³/h max. + pre- and intermediate filter 2500 m³/h 3000 m³/h (EU3, EU4) max.
Instruction Manual Negative Pressure Unit green dec 4.5. Performance data G 400 Air performance, free-blowing max. 9500 m³/h + deconta H13 or H14 filter 8400 m³/h max. + pre- and intermediate filter 7800 m³/h (EU3, EU4) max. Power connection 400 V...
Instruction Manual Negative Pressure Unit green dec 4.7. Connections, dimensions, weights G 500 G 50 G 55 G 100 G 200 G 300 G 400 Filter unit Fan unit FG 500 Hose connection option exhaust air Hose connection option option option option 2x 450...
Instruction Manual Negative Pressure Unit green dec 4.8. Filter description / classification Integrated in the device is a 3-stage filter combination (G 50 only 2-stages). In particular: Pre-filter and intermediate filter Pre-filter Intermediate filter Quality class acc. to DIN 24185 / EN 779 G3 / EU3 G4 / EU4 Cardboard frame,...
Page 14
Instruction Manual Negative Pressure Unit green dec HEPA filter Frame Plastic Filter medium Micro fiberglass paper Casting compound Polyurethane Seal Polyurethane Filter class H13 or H 14 acc. to EN 1822 70°C/100% RH Temperature / humidity (relative humidity) Filter dimensions (in mm): ...
Instruction Manual Negative Pressure Unit green dec 5. Technical description 5.1. Unit description Negative Pressure Unit for filtering asbestos-contaminated room air via a 3-stage filter unit (G 50 only 2-stages). The built-in HEPA filter meets the requirements of EN 1822 class H13 or H14.
Instruction Manual Negative Pressure Unit green dec The control of the Negative Pressure Unit (NPU) is optionally available in the following versions: 5.2. Control SE For power regulation, NPU is supplied with a manual speed controller. 5.3. Control SRE + For power regulation, the NPU is supplied with a PLC control via a touch display in order to measure and regulate the negative pressure or the volume flow.
Instruction Manual Negative Pressure Unit green dec 5.4. Control SRE connect IoT (Internet of Things) => Devices with SRE connect control can be remotely controlled and monitored with any internet-enabled computer, mobile phone or tablet. For power regulation, the negative pressure unit is supplied with a control via a touch display to measure and regulate the negative pressure and / or the volume flow.
The Negative Pressure Unit is shipped ready-to-use from the factory and is intended for immediate commissioning. In case of visible damage, do not operate the unit. Please contact deconta GmbH immediately. Please note: In principle, the negative pressure unit can also be operated directly in the contaminated area (overpressure technology prevents the penetration of contaminated ambient air into the housing).
Instruction Manual Negative Pressure Unit green dec 7. Initial operation 7.1. Control SE For power regulation, the negative pressure unit is supplied with a manual speed controller. Connect the power supply Operate the controller 7.1.1. Room pressurisation Set the required negative pressure at the air intake or at the manual speed controller ...
Instruction Manual Negative Pressure Unit green dec 7.2. Control SRE + Set the measuring point in the contaminated area and connect it to the negative pressure connection with the PE hose 8 x 1 Determine the measuring point in the clean area (adjoining rooms) and connect to the atmosphere connection with PE hose 8 x 1 connection atmosphäre...
Instruction Manual Negative Pressure Unit green dec 7.2.1. Set display language language setting Tap on the speech bubble button to see the display for setting the display language. Version 1 Page 21...
Instruction Manual Negative Pressure Unit green dec 7.2.2. Language table The illustrations in this operating instruction show the displays in English language. Translations of the display texts can be found in the following language table. english deutsch français automatic Automatik Automatique delay time on Einschaltverzögerung...
Page 23
Instruction Manual Negative Pressure Unit green dec english italiano español automatic automatico Automático delay time on avvio ritardato Activac. retardada close fine Filter filtro Filtro Check Filter controllo filtro Test filtro Filter change cambio filtro Cambio filtro Year anno Año Calibration Load Cell calibrazione canale di misurazione Calibración canal No HEPA filter?
Page 24
Instruction Manual Negative Pressure Unit green dec 日本の english nederlands 自動 automatic Automatisch 動作モード遅延時間 delay time on Vertragingstijd op 閉じる close Einde フィルター Filter Filter フィルターチェック Check Filter Controle filter フィルター交換 Filter change Filter wisselen 年 Year Jaar ロードセル校正 Calibration Load Cell Kalibratie meetsensor HEPAフィルターの装着忘れ?...
Instruction Manual Negative Pressure Unit green dec The control can be used in 3 different operating modes. The active mode is highlighted with a blue background. 7.2.3. Manual mode In manual operation mode, the fan power is specified with the "+" and "-" buttons. The display shows the performance value in%, the measured negative pressure in Pa, the volume flow in m³...
Instruction Manual Negative Pressure Unit green dec 7.2.4. Automatic operation negative pressure In the automatic operation negative pressure, the set point in Pascal for the negative pressure is set with the "+" and "-" keys. By comparing the entered set value with the permanently measured current actual value, the speed of the fan is automatically adjusted meaning the fan runs automatically "up"...
Page 27
Instruction Manual Negative Pressure Unit green dec If the negative pressure unit does not reach the specified setpoint, the following error message is displayed after the delay time set in the setup menu (Alarm < Set point after) and an acoustic signal sounds. Version 1 Page 27...
Instruction Manual Negative Pressure Unit green dec 7.2.5. Automatic operation volume flow In the automatic operation volume flow, the setpoint in Pascal is set with the "+" and "-" keys in m³/h and cfm for the volume flow. By comparing the entered setpoint with the permanently measured current actual value, the speed of the fan is automatically adjusted meaning the fan runs automatically "up"...
Page 29
Instruction Manual Negative Pressure Unit green dec If the negative pressure unit does not reach the specified setpoint, the following error message is displayed after the delay time set in the setup menu (Alarm < Set point after) and an acoustic signal sounds. Version 1 Page 29...
Instruction Manual Negative Pressure Unit green dec 7.2.6. Changing operation mode By touching the button "settings", the operating mode of the negative pressure unit can be changed. settings The unit is in manual operation. Switch to automatic mode by tapping the "Set" button. The display changes to the selection of the automatic mode.
Instruction Manual Negative Pressure Unit green dec Um Schäden zu vermeiden kann in der Betriebsart „Automatikbetrieb Volumenstrom“ der Volumenstrom durch die Eingabe eines maximal erlaubten Unterdrucks begrenzt werden (max -Pa). Durch Tippen auf den Button „Close“ wird das Einstellungsmenü verlassen. 7.2.7.
Page 32
Instruction Manual Negative Pressure Unit green dec The stand-by mode is shown in the display as follows. If the device detects a too low negative pressure, the elapsing delay time is shown on the display. After the expiration, the device switches on automatically with its preset values.
Instruction Manual Negative Pressure Unit green dec 7.2.8. Filter sensor A filter sensor monitors the particle concentration in the exhaust air. The state of the filter sensor is shown on the display. Display filter sensor An optical and acoustic alarm is triggered, if a value of 100 particles per liter is permanently exceeded in the exhaust air.
Instruction Manual Negative Pressure Unit green dec 7.2.9. Additional settings time / date acoustic signal By tapping the button with the speaker symbol, the acoustic signal can be switched on or off. By tapping the button with the clock symbol (time / date), a display with further settings is shown.
Instruction Manual Negative Pressure Unit green dec 7.2.10. Warnings and indications The filter occupancy is displayed in 5 steps. Filter occupancy A necessary filter change is indicated by the message "filter change" and an acoustic signal sounds. After the change, the warning must be acknowledged by tapping the "OK" button. The Negative Pressure Unit detects whether a HEPA filter is installed.
Instruction Manual Negative Pressure Unit green dec 7.3. Control SRE connect The connect functions are supported by default in the following countries: Albania, Algeria, Armenia, Aruba, Australia, Austria, Azerbaijan, Bangladesh, Belarus, Belgium, Bolivia, Bonaire, Bulgaria, Cambodia, China, Croatia, Curacao, Cyprus, Czech Republic, Denmark, El Salvador, Estonia, Faroe Islands, Finland, France, French Guyana, Georgia, Germany, Ghana, Gibraltar, Greece, Guadeloupe, Guyana, Honduras, Hong Kong, Hungary, Iceland, Indonesia, Ireland, Israel, Italy, Japan, Jersey, Kazakhstan,...
Negative Pressure Unit green dec 7.3.1. Create your user account Open the website www.deconta-connect.com in your internet browser. Press the tab „Sign Up“ and enter your e-mail address and desired password. The password must be at least 8 characters long and must meet 3 of the following 4 criteria: ...
7.3.2. Add the device to your user account Turn on your device. Press the button „Menu“. Press the button „Service“. Press the button „deconta connect“. The page with a QR code and below a key are displayed. Version 1 Page 38...
Page 39
Instruction Manual Negative Pressure Unit green dec Log in with your e-mail address and with your password on the connect page. Press the menu icon and then choose „Devices“. Press button „SCAN CODE (our recommendation) or alternatively press the button „SOFTWARE KEY“.
Page 40
Instruction Manual Negative Pressure Unit green dec Scan the QR code, that appears on the device’s display. If the QR code is detected, the button „SUBMIT“ changes to green. In order to add the device, press this button. Now the device is registered in your user account. Alternative registration via the button „SOFTWARE KEY“.
Instruction Manual Negative Pressure Unit green dec Preparation: Set the measuring point in the contaminated area and connect it to the negative pressure connection with the PE hose 8 x 1 Determine the measuring point in the clean area (adjoining rooms) and connect to the atmosphere “+”...
Instruction Manual Negative Pressure Unit green dec 7.3.4. Automatic mode To make the settings and turn on / off the automatic mode, press the "Menu" button. In the following menu press on the button "Automatic mode settings". The following parameters can be set: •...
Instruction Manual Negative Pressure Unit green dec 7.3.5. Day / Night setting By selecting time ranges, it is possible to set on which days and at what time the value set in automatic mode for the minimum negative pressure in night mode is activated. 7.3.6.
Instruction Manual Negative Pressure Unit green dec 7.3.7. Consumption Left: displays the actual performance of the device in %. Middle top: displays the actual consumption (Actual current) in A. Middle down: displays the actual power in kW Right: displays the watt hours and below the total consumption in KWh 7.3.8.
Negative Pressure Unit green dec 7.3.9. Service deconta connect Allocate the device to a connect account (see point 7.3.2.). Maintenance Settings in this menu can only be made by qualified deconta service partners. Software packages See point 7.3.10. Version 1 Page 45...
Instruction Manual Negative Pressure Unit green dec System settings Setting the day of the week and time. These values are displayed on the device display and are required for day / night settings. Data sent to the connect user account are displayed there in the set time zone (default UTC ±...
Instruction Manual Negative Pressure Unit green dec 7.3.11. Device information Display of device information. 7.3.12. Alarms Alarms are visually displayed via a flashing icon on the main screen. At the same time, an acoustic signal sounds. There are 3 different icons: green tick: there is no alarm message.
Page 48
Instruction Manual Negative Pressure Unit green dec A submenu with details about alarms can be called by pressing the button with the green tick, the yellow bell or the red bell. Alarms are displayed with a red button. After eliminating the fault, the alarm must be acknowledged by pressing on the respective button.
Instruction Manual Negative Pressure Unit green dec Stop dust sensor / Start dust sensor: - Turn on / off the dust sensors. Please note: when the sensors are switched off, the particle concentration in the exhaust air is not monitored! 7.3.13.
The test result shall be presented on request. Devices with SRE connect control should be checked and calibrated once a year by the deconta service. 8.1. Information on filter change The frequency of the filter change depends on the degree of contamination of the filters.
Instruction Manual Negative Pressure Unit green dec Recommended filter change at Device 110 V 230 V G 50 / G 55 approx. 700 Pascal approx. 800 Pascal G 100 approx. 700 Pascal approx. 1000 Pascal G 200 approx. 700 Pascal approx.
Instruction Manual Negative Pressure Unit green dec A necessary filter change is indicated by the message "filter change" and an acoustic signal sounds. After the change, the warning must be acknowledged by tapping the "OK" button. If the display shows the value for the recommended filter change, first exchange the pre- and intermediate filter.
Instruction Manual Negative Pressure Unit green dec 8.2. Filter change Attention: Contaminated filters must only be changed while observing all relevant safety precautions Change the filter only when the unit is switched off Use only approved filters ...
Page 54
Instruction Manual Negative Pressure Unit green dec Unscrew hexagon socket screws using the supplied hex wrench hex wrench Remove the housing frame Remove HEPA filter and dispose it Version 1 Page 54...
Page 55
HEPA filters H14. In order to ensure machine safety, only original deconta filters should be used. The machine safety cannot be guaranteed if this is not observed. This may result in the risk of hazardous substances being released into the environment due to a filter overload (leakage, filter crack, ...) in an...
Page 56
Instruction Manual Negative Pressure Unit green dec Clean the housing on the inside Insert the new HEPA filter in the centre Insert the housing frame and hexagon socket screws (tighten the screws evenly) Insert the pre- and intermediate filter ...
Get the power source checked and Unit does not work Power source out of order repaired by a qualified technician Defective components on Have the unit repaired by deconta or a Unit does not work the negative pressure unit workshop authorized by deconta Version 1...
The changed technical data can be taken from the following tables. G 200 Air performance, free-blowing max. 4500 m³/h + 2 x deconta HEPA filter H13 or H14 3200 m³/h max. + Pre-filter and intermediate filter 2800 m³/h (EU3, EU4) max.
Instruction Manual Negative Pressure Unit green dec 11. Sound level measurement value in dB (A) Status: 100% motor power, outdoor area Device G 50 / 55 G 100 G 200 G 300 G 400 G 500 By attaching a silencer, the sound level can be reduced in consideration of power losses. Version 1 Page 59...
Negative Pressure Unit green dec 12. Declaration of Conformity EC Declaration of Conformity acc. to Machinery Directive 2006/42 / EC Annex II 1.A The manufacturer deconta GmbH Im Geer 20 46419 Isselburg hereby declares that the following product Product designation:...