Func-
Parameter
Name
tion
0
Torque boost
1
Maximum frequency
2
Minimum frequency
3
Base frequency
4
Multi-speed setting (high speed)
5
Multi-speed setting (middle speed)
6
Multi-speed setting (low speed)
7
Acceleration time
8
Deceleration time
9
Electronic thermal O/L relay
10
DC injection brake operation frequency 0 to 120Hz
11
DC injection brake operation time
12
DC injection brake operation voltage
13
Starting frequency
14
Load pattern selection
15
Jog frequency
16
Jog acceleration/deceleration time
17
MRS input selection
18
High speed maximum frequency
19
Base frequency voltage
Acceleration/deceleration reference
20
frequency
Acceleration/deceleration time
21
increments
22
Stall prevention operation level
Stall prevention operation level
23
compensation factor at double speed
24
Multi-speed setting (speed 4)
25
Multi-speed setting (speed 5)
26
Multi-speed setting (speed 6)
27
Multi-speed setting (speed 7)
Acceleration/deceleration pattern
29
selection
60
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0 to 30%
0.1%
6/4/3/2%
83
∗1
0 to 120Hz
0.01Hz
120Hz
95
0 to 120Hz
0.01Hz
0Hz
95
0 to 400Hz
0.01Hz
60Hz
97
0 to 400Hz
0.01Hz
60Hz
101
0 to 400Hz
0.01Hz
30Hz
101
0 to 400Hz
0.01Hz
10Hz
101
0 to 3600/360s
0.1/0.01s
5/10/15s
108
∗2
0 to 3600/360s
0.1/0.01s
5/10/15s
108
∗2
Rated
0 to 500A
0.01A
inverter
115
current
0.01Hz
3Hz
127
0 to 10s
0.1s
0.5s
127
0 to 30%
0.1%
6/4/2%
127
∗3
0 to 60Hz
0.01Hz
0.5Hz
111
0 to 3
1
0
99
0 to 400Hz
0.01Hz
5Hz
103
0 to 3600/360s
0.1/0.01s
0.5s
103
0, 2, 4
1
0
140
120 to 400Hz
0.01Hz
120Hz
95
0 to 1000V, 8888, 9999
0.1V
9999
97
1 to 400Hz
0.01Hz
60Hz
108
0, 1
1
0
108
0 to 200%
0.1%
150%
91
0 to 200%, 9999
0.1%
9999
91
0 to 400Hz, 9999
0.01Hz
9999
101
0 to 400Hz, 9999
0.01Hz
9999
101
0 to 400Hz, 9999
0.01Hz
9999
101
0 to 400Hz, 9999
0.01Hz
9999
101
0, 1, 2
1
0
112
Symbol in the Remarks columm.
... Specifications differ according to the date assembled. Refer to page 330 to check the SERIAL number.
Symbols in the table indicate parameters which function when an option is mounted.
......... FR-A7AX E kit,
......... FR-A7NP E kit
These instruction codes are used for parameter read and write by using Mitsubishi inverter protocol with the RS-485 communication.
(Refer to page 213 for RS-485 communication)
" " indicates valid and "×" indicates invalid of "control mode-based correspondence table", "parameter copy", "parameter clear", and "all parameter clear".
Customer
Parameter
Remarks
Setting
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
29
..... FR-A7AY E kit,
....... FR-A7AR E kit,
.... FR-A7NC E kit,
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
AD MFVC
AD MFVC
AD MFVC
×
00
80
0
01
81
0
02
82
0
×
03
83
0
04
84
0
05
85
0
06
86
0
07
87
0
08
88
0
09
89
0
0A
8A
0
0B
8B
0
0C
8C
0
0D
8D
0
0E
8E
0
×
0F
8F
0
10
90
0
11
91
0
12
92
0
13
93
0
×
14
94
0
15
95
0
16
96
0
17
97
0
18
98
0
19
99
0
1A
9A
0
1B
9B
0
1D
9D
0
Parameter list
.... FR-A7ND E kit,
......FR-A7NL E kit,
Parameter
Copy
Clear
All clear
GP MFVC
GP MFVC
GP MFVC
×
×
×
4
×

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents