Mitsubishi Electric FR-E720-008 Instruction Manual page 77

Hide thumbs Also See for FR-E720-008:
Table of Contents

Advertisement

Parameter list
Func-
Parameter
Name
tion
990
PU buzzer control
991
PU contrast adjustment
Pr.CL
Parameter clear
ALLC
All parameter clear
Er.CL
Faults history clear
Pr.CH
Initial value change list
∗1
Differ according to capacities.
6%: FR-E720-050(SC) or less, FR-E740-026(SC) or less, FR-E720S-050 or less, FR-E710W-050 or less
4%: FR-E720-080(SC) to175(SC), FR-E740-040(SC) to 095(SC), FR-E720S-080 and 110
3%: FR-E720-240(SC) and 330(SC), FR-E740-120(SC) and 170(SC)
2%: FR-E720-470(SC) and 600(SC), FR-E740-230(SC) and 300(SC)
∗2
Differ according to capacities.
5s: FR-E720-175(SC) or less, FR-E740-095(SC) or less, FR-E720S-110 or less, FR-E710W-050 or less
10s: FR-E720-240(SC) and 330(SC), FR-E740-120(SC) and 170(SC)
15s: FR-E720-470(SC) and 600(SC), FR-E740-230(SC) and 300(SC)
∗3
Differ according to capacities.
6%: FR-E720-008(SC) and 015(SC), FR-E720S-008 and 015, FR-E710W-008 and 015
4%: FR-E720-030(SC) to 330(SC), FR-E740-016(SC) to 170(SC), FR-E720S-030 to 110, FR-E710W-030 and 050
2%: FR-E720-470(SC) and 600(SC), FR-E740-230(SC) and 300(SC)
∗4
Write is disabled in the communication mode (Network operation mode) from the PU connector.
∗5
The initial value differs according to the voltage class. (100V, 200V class/400V class)
∗6
The range differs according to the Pr. 71 setting.
∗7
Theses parameters can be set only in the safety stop function model.
∗8
The parameter number in parentheses is the one for use with the operation panel (PA02) for the FR-E500 series or parameter unit (FR-PU04/FR-PU07).
∗9
These parameters are communication parameters that are not cleared when parameter clear (all clear) is executed from RS-485 communication. (Refer to
page 213 for RS-485 communication).
∗10 When a communication option is installed, parameter clear (lock release) during password lock (Pr. 297 ≠ 9999) can be performed only from the
communication option.
∗11 Available only for the three-phase power input model.
76
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0, 1
1
1
275
0 to 63
1
58
275
0, 1
1
0
276
0, 1
1
0
276
0, 1
1
0
278
277
Customer
Parameter
Remarks
Setting
990
991
Pr.CL
ALLC
Er.CL
Pr.CH
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
AD MFVC
AD MFVC
AD MFVC
GP MFVC
GP MFVC
GP MFVC
5A
DA
9
5B
DB
9
FC
FC
F4
Parameter list
Parameter
Copy
Clear
All clear
×
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents