SITRANS FM100
Index
Name
[hex]
0x03DC
SimMode
0x03DD
SimStartValue
0x03E1
SimIncrement
Value
0x03E5
SimNumber
Intervals
0x03E7
SimTimingIntervals Timinig [ms]
0x03E9
ValueInSiUnit
0x03ED
MinValueInSiUnit
0x03F1
MaxValueInSiUnit
Part Volume
0x0421
CountingType
0x0426
Unit
0x0427
UserUnit
0x0440
SimMode
page 66
Description
Factory default
Mode of the
0
Simulation:
Static,Triangle or
Monotonic
Value to start with
0,0
the simulation
Incrementation
10,0
value of the
simulation
Number of
20
intervals to
simulation
50
between intervals
Saved temperature
0,0
value in SI unit [°C]
Saved min
0,0
temperature value
in SI unit [°C]
Saved max
0,0
temperature value
in SI unit [°C]
counting type for a
0
volume slot ->
absolute or
bidirectional
Unit used for part
1
volume
User Unit used for
1,0
part volume
Mode of the
0
Simulation:
Static, Triangle or
Monotonic
Max Value
Min Value
(0) - Static
(1) - Triangle
(2) - Monotonic
9999,0
-9999,0
999,0
-999,0
65000
1
50000
50
999999,0
-999999,0
999999,0
-999999,0
999999,0
-999999,0
(0) - absolute
(1) - bidirectional
(0) - USER
(1) - L
(2) - mL
(3) - m3
(4) - galUS
(5) - galUK
(6) - Barrel
9999,9
0,0
(0) - Static
(1) - Triangle
(2) - Monotonic
Length
Data Type
Access
[Bytes]
1
UIntegerT
R/W
4
FloatT
R/W
4
FloatT
R/W
2
UIntegerT
R/W
2
UIntegerT
R/W
4
FloatT
R
4
FloatT
R
4
FloatT
R
1
UIntegerT
R/W
1
UIntegerT
R/W
4
FloatT
R/W
1
UIntegerT
R/W