(1) General Bypass
a. Hold the knob or use a bypass tool to rotate the knobs. The water supply will be bypassed
when the knobs are horizontal. The bypass valve is in service when knobs are oriented
vertically. When the bypass valve is in service, users can take raw water and filter water
samples for testing at the water-taking port on either side of the bypass.
b. In case of equipment failure or other exceptional circumstances, the bypass can be adjusted to
the bypass position, allowing users to use tap water temporarily. After the failure or problem is
resolved, adjust the bypass to the vertical service position
c. Users can adjust the Water Hardness Adjustment Nut to achieve their desired water hardness.
d. Rotate the Water Hardness Adjustment Nut in a clockwise direction. The bigger the rotation
angle, the higher the water hardness.
(2) Before Installation
Verify the water source pressure; the acceptable range is 21 psi - 64 psi. If the pressure is higher
or lower than this, it is recommended to install a pressure stabilizer.
Do not remove the clips when the system is in operation; relieve the pressure before removing
the clips.
(3) Equipment Installation
It is highly recommended that you watch the video How to Install iSpring WCS45KG Whole
House Water Central Softener | DIY Installation on YouTube.