Ispring WHOLE HOUSE WCS45KG Installation Instructions & User Manual page 16

Central softener
Hide thumbs Also See for WHOLE HOUSE WCS45KG:
Table of Contents

Advertisement

b. Factory Options
Press and hold "Menu" and "Set/Regen" or "SETTINGS" and "MANUAL REGEN." at the
same time for 3 seconds to enter.
Press "Set/Regen" or "MANUAL REGEN." to confirm and switch to the following parameter
setting, the entire menu shown below. Use the "UP" and "DOWN" buttons to modify the value.
Press the "Menu" or "SETTINGS" button to return to the standby state immediately.
Page 14
www.123filter.com
SYSTEM LANGUAGE:
Choose the system language.
UNITS:
Choose the system's unit of measurement: metric or gallons.
EFFICIENCY & CAPACITY SETTINGS:
There are 3 settings to choose from: High Efficiency, Standard
Capacity, and Iron & Manganese.The values for these settings are
set in the Factory Options and are used to calculate the system
capacity and refill time.
REFILL:
This value should match the BLFC flow washer. It is used to
calculate the refill time.
BRINE MAKE TIME:
This value is the time allowed for the salt to dissolve in the water
to create the brine solution. It is the amount of time ahead of the
scheduled regeneration time that the water will be added to "top
off" the brine already prepared in the brine tank.
BRINE PRE-FILL%:
This is the percentage of water that will be added to the brine tank
after a regeneration. The default is 70%. The remaining water will
be added just prior to the regeneration and will be proportional to
the amount of capacity left in the system.
DAILY RESERVE:
This value is used to calculate the reserve capacity. Reserve
Capacity = # of People x DAILY RESERVE. The 4-day option is
used to calculate the daily water consumption for 28 days, and the
average daily water consumption for each day of the week is
calculated separately.
BW. (RINSE) OVERRIDE:
This setting can be used to skip the backwash (rinse) cycle. As an
example, if the setting is 10, the system will skip 10 backwash
(rinse) cycles. The setting will only work if the WATER SOURCE is
set to MUNICPAL for clean water applications.
FORCED REGEN:
When set to ON, the system will start a forcedregeneration when
the remaining capacity reaches 3% and when no water is used for
10 minutes. The regeneration consists of 20 minutes of Brine and
10 minutes of Rinse. The 30 minute regeneration willrestore up to
33% of the system capacity. At the next regeneration time (2:00
a.m.), the system
regeneration to restore capacity to 100%.
SMART CLEAN:
When set to ON, the system will perform a 10 minute (adjustable)
backwash and rinse if there is no water flow detected after 7 days
(adjustable). The regeneration will occur at the scheduled REGEN
TIME.