Descaling Frequency - Saeco PRIMEA LINE Technical & Service Manual

Table of Contents

Advertisement

6.4
Aqua Prima
Operating logic with "AQUA PRIMA" filter for Primea Ring
When use of the "aqua prima" filter is selected on the user menu or via the control panel, the
system water count logic is as follows:
If the "aqua prima" function has been enabled, the electronics perform a pulse count of the
turbine, recording one pulse every 2 revolutions.
If the "aqua prima" function has been disabled, the electronics perform a pulse count of the
turbine, recording one pulse every revolution.
The graph below illustrates this function:
Hard-
Water hardness
ness
1
Soft water
2
Medium water (7º-14ºdH)
3
Hard water
4
Very hard water (over 21ºdH) Approx. every 4 weeks / 30 litres
Operating logic with "AQUA PRIMA" filter for Primea Ring Duo - Touch Plus and Touch
When the "Aqua Prima" is enabled, an additional 30l of water can go through before descaling is re-
quired (see table)
Hard-
Water hardness
ness
1
Soft water
2
Medium water (7º-14ºdH)
3
Hard water
4
Very hard water (over 21ºdH) Approx. every 4 weeks / 30 litres
PRIMEA Chapter 06
REV. 02 - Mar. 07
Prima water
O N
Prima water
O F F
360°
(1 rev)
= 1 PULSE
(up to 7ºdH)
Approx. every 3 months/120 litres
Approx. every 2 months / 90 litres
(15º-21ºdH)
Approx. every 6 weeks / 60 litres
(up to 7ºdH) Approx. every 3 months/120 litres Approx. every 3 months/150 litres
Approx. every 2 months / 90 litres Approx. every 2 months/120 litres
(15º-21ºdH)
Approx. every 6 weeks / 60 litres
360°
360°
(1 rev)
(1 rev)
Descaling
Descaling
frequency
DESCALING
Descaling
frequency
Turbine
revs
360°
(1 rev)

Descaling frequency

when usingAqua Prima
Approx. every 3 months/240 litres
Approx. every 2 months/180 litres
Approx. every 6 weeks / 120 litres
Approx. every 4 weeks / 60 litres
Descaling
frequency
when usingAqua Prima
Approx. every 6 weeks / 90 litres
Approx. every 4 weeks / 60 litres
7/9