Saeco PRIMEA LINE Technical & Service Manual page 41

Table of Contents

Advertisement

SYSTEM SETTINGS
5.4.5 Ring system settings
PARAMETERS
SETTING
Water heater temperature enabled
Water heater temperature disabled
Steam heater temperature enabled
Steam heater temperature disabled
Normal cup temperature
BEVERAGE PARAMETERS
Hot water
Hot milk (pulse length)
Hot milk (impulse period)
MILK CIRCUIT RINSE
Dispense time
Impulse length
Pulse period
MILK CIRCUIT CLEANING
Milk circuit cleaning (dispense time)
MILK CIRCUIT CLEANING MESSAGES
cleaning time
days before notification
days till block
Stop coffee grounds
Coffee grounds counter
Water reserve limit
Serial number
Stand - by (energy saving)
PRIMEA Chapter 05
REV. 02 - Mar. 07
Unit of
measure
Settings range
°C
°C
°C
°C
°C
Flow rate (l/h)
line-period
20 ms - steps
seconds
line-period
20 ms - steps
seconds
days
days
no. grounds
no. grounds
turbine pulses
hours / minutes
Default value
70 ... 150
70 ... 150
70 ... 150
70 ... 150
70 ... 150
5 ... 31
1 ... 9 5 (=100 ms/50 Hz)
5 ... 250
60(=1200 ms)
0 ... 40
1 ... 3 1 (= 20 ms / 50 Hz)
5 ... 250
15 (=300 ms)
0 ... 40
0 ... 25
0 ... 25
0 ... 2000
0-3 / 0-59
18/20
130
115
150
130
78
18
10
10
30
14
21
24
24
750
3