Placement; Alignment - Sub-Zero DEU1550B/L Installation Manual

Undercounter refrigeration
Hide thumbs Also See for DEU1550B/L:
Table of Contents

Advertisement

Available languages

Available languages

Installation

Placement

CAUTION
Before moving the unit into position, secure the door
closed and protect any finished flooring.
WARNING
When positioning the appliance, ensure the supply
cord is not trapped or damaged.
Use an appliance dolly to move the unit near the opening.
If the unit has been on its back or side, it must stand
upright for a minimum of 24 hours before connecting
power.
Plug the power cord into the grounded outlet. For model
DEU2450CI, insert the water supply line into the hole on
the back of the unit. Refer to the illustration below. Pull the
excess water line forward as the unit is slid into the open-
ing. Verify the anti-tip bracket is properly engaged.
HOLE FOR
WATER LINE
BACK OF UNIT
Water line (model DEU2450CI)
8 | Sub-Zero Customer Care 800.222.7820

Alignment

LEVELING
Once the unit is in position, rotate the front legs clockwise
to raise and counterclockwise to lower. Rear height adjust-
ment can be made from the front. Using a Phillips drive,
turn clockwise to raise the unit or counterclockwise to
lower. Use the lowest torque setting when using a power
drill. Do not turn the leveling legs by hand. Refer to the
illustration below.
When the unit is properly leveled, door adjustments are
less likely to be necessary.
IMPORTANT NOTE: Level the unit to the floor, not the
surrounding cabinetry. This could affect the operation of
the unit, such as door closing.
WARNING
To reduce the possibility of the unit tipping forward,
the front leveling legs must be in contact with the
floor.
FRONT
REAR
ADJUSTMENT
ADJUSTMENT
Leveling

Advertisement

Table of Contents
loading

Table of Contents