Plumbing Requirements; Preparation - Sub-Zero DEU1550B/L Installation Manual

Undercounter refrigeration
Hide thumbs Also See for DEU1550B/L:
Table of Contents

Advertisement

Available languages

Available languages

Site Preparation

Plumbing Requirements

MODEL DEU2450CI
Installation must comply with all applicable plumbing
codes.
For ease of installation, recess the water shut-off into the
wall or place it in an adjacent cabinet. Locate the water
supply line within the shaded area shown in the illustra-
tion below. Connect the water supply line to the house
supply with an easily accessible shut-off valve. Do not use
self-piercing valves.
An in-line filter is required when water conditions have a
high sediment content.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
to the unit at all times. A copper line is not recommended
for this application.
PLUMBING REQUIREMENTS
Water Supply Line
Water Pressure
Excess Water Line for Connection
OPENING
2"
2"
(51)
(51)
4"
(102)
AREA EXTENDS
1
/
"
2
(13) FORWARD ON FLOOR
Water supply location
6 | Sub-Zero Customer Care 800.222.7820
supplied
(2.4–8.3 bar)
1/4" OD copper, braided
stainless steel, or PEX tubing
35–120 psi
(2.4–8.3 bar)
5'
(1.5 m)

Preparation

Uncrate the unit and inspect for damage. Remove and
recycle packing materials. Do not discard the kickplate,
anti-tip bracket, and hardware.
Remove the kickplate by extracting the two mounting
screws. Refer to the illustration below.
SCREW
Kickplate removal