MAIN CHARACTERISTICS

Total capacity
DHW circuit capacity
Coil capacity (primary circuit)
Primary pressure drop *
Coil heating surface
Max. Design Pressure * (Primary)
Max. Design Pressure * (DHW)
EN
Reheat Performance - Primary Heating Power Input *
Primary flow rate (to achieve Reheat Performance) *
Reheat time (heating source = internal coil)
Equivalent capacity at 40°C
Standing Heat Loss*
Empty weight
* According to EN12897:2016
Conditions : Primary circuit temperature : 80°C,

MAXIMUM OPERATING CONDITIONS

Max. operating pressure - primary
Max. operating pressure - DHW
Supply pressure (DHW circuit)
Maximum temperature - primary side
Maximum temperature - DHW side
Water quality (primary and DHW circuits)
EN -
6

Technical Characteristics

water intake temperature : 10°C
Domestic hot water (DHW) : 60°C
L
L
L
mbar
bar
bar
kW
L/s
min
L
kWh/24h
W
kg
Water Heater
bar
bar
bar
°C
°C
Water from the distribution network.
Chlorides < 150 mg/L
6 ≤ pH ≤ 8
9°fH ≤ hardness ≤ 20°fH. The use of
water softener is recommended.
661Y3400 • A
Water Heater
297
275
22
48.5
3.6
5
8
106
0.25
20
439
2.12
83
75
5
8
4.5
90
90

Advertisement