Description; Technical Characteristics - Atlantic Calypso FS 172L Installation Manual

Table of Contents

Advertisement

Warnings
1.

Technical Characteristics

Product Details
Product reference
Model Code/Number
Product Name
Heat Pump Performance
Air operating range (ducted configuration)
Air operating range (Ambient air configuration)
Achievable hot water temp via heat pump
Max. electrical power input (heat pump AND
immersion)
Max.Thermal power output from heat pump
ONLY at 45°C
Air flow
Sound power level
Refrigerant
Air ducting method
Coefficient of performance (M profile, 7°C)
Energy efficiency (ηwh)
Heating time from cold (10°C to 54°C)
Standing power input
Maximum usable hot water volume (V40,
EN16147(2017))
Presure loss during test
Airflow during test
Coefficient of performance (L profile,7 °C)
Energy efficiency (ηwh)
Heating time from cold (10°C to 54°C)
Standing power input
Maximum usable hot water volume (V40,
EN16147(2017))
Presure loss during test
Airflow during test

Description

Installation
DESCRIPTION
°C
°C
°C
W
W
m³/h
dB(A)
-/kg
-
%
h
W
litres
Pa
m3/h
-
%
h
W
litres
Pa
m3/h
Maintenance
CALYPSO FS 172L
AH876509
ATL CV4 STAINLESS
ATL CV4 STAINLESS
STEEL FS 172L
-5 to 43
5 to 43
62
650 + 1600 = 2250
1345
Nominal air flow 400m3/hr to 240m3/hr with
associated maximum ducting pressure drop
50Pa to 150Pa.
49
R134a / 0,85kg
Separate inlet & outlet to exterior
2.78
117.0
5h48
19
228.0
60.0
387.0
3.15
129.40
5h44
17
227.0
58
386.0
CALYPSO FS 210L
AH886123
STEEL FS 210L
R134a / 0,86kg
2.81
118.4
7h18
19
285.2
54.3
402.6
3.02
124.35
7h27
20
285.1
57
391.6
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Calypso fs 210lAh876509Ah886123

Table of Contents