Testing Procedures; Component Testing - Maytag JENN-AIR JDR8895AAB Service Manual

Freestanding double oven dual fuel range
Table of Contents

Advertisement

Testing Procedures

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing,
unless testing requires power and/or gas.

Component Testing

Illustration
Oven light socket
Autolatch assembly
with switch
5 K btu
270° valve
9.2 K btu (2)
16 K btu
12 K btu
Spark 270° switch
Spark ignition
electrode
5 K btu
Top surface burner
9.2 K btu (2)
16 K btu
12 K btu
Spark module 4 + 0
L
A
B
N
A1
B1
Temperature sensor
Pressure regulator
Door plunger switch
Bake element, Upper
Bake element, Lower
Broil element, Upper
16
!
WARNING
Component
Test Procedure
Remove one wire from receptacle
and test resistance of terminals........
Measure voltage at oven light...........
Disconnect wires and test for
continuity per wiring diagram.
Refer to Parts Manual for correct
autolatch switch associated with the
correct manufacturing number.
Verify gas is supplied.
Adjust set screw for simmer control.
Test for voltage at terminals .............
Disconnect wiring and check for
continuity in LITE position.................
Test for resistance of spark lead ......
Test ignitor to chassis.......................
Verify gas is supplied .......................
Verify burner cap is positioned
correctly.
Test for voltage at terminals L and N
Check polarity and ground................
Measure resistances ........................
Verify gas pressure (W.C.P.).
If on LP service verify proper gas
supply conversion.
Remove switch from unit and
measure the following points:
C NO.............................................
Disconnect wire leads to element
and measure resistance of terminals
Measure voltage at bake element.....
Disconnect wire leads to element
and measure resistance of terminals
Measure voltage at bake element.....
Disconnect wire leads to element
and measure resistance of terminals
Measure voltage at broil element......
16023417
Get other manuals https://www.bkmanuals.com
Results
Indicates continuity with bulb screwed in.
120 VAC, see wiring diagram for terminal
identification.
If no voltage is present at oven light, check
wiring or light switches.
See wiring diagram for schematic layout.
Access assembly by removing left side
panel.
120 VAC
Continuity in LITE position.
Continuity
No continuity from ignitor to chassis.
Check for obstructions in burner ports.
120 VAC
See wiring diagram
Approximately 1100 Ω at room temperature
75°F.
5" Natural
10" LP/propane
Plunger in infinite, Plunger out continuity.
Approximately 31.0 Ω, if not replace.
240 VAC, see wiring diagram for terminal
identification. If no voltage is present at
bake element check wiring.
Approximately 21.3 Ω, if not replace.
240 VAC, see wiring diagram for terminal
identification. If no voltage is present at
bake element check wiring.
Approximately 25.4 Ω, if not replace.
240 VAC, see wiring diagram for terminal
identification. If no voltage is present at
broil element check wiring.
©2004 Maytag Services