5.2 Reading the Display

Cell On
Cell Resting
Flow or No Flow Indication
Cell Reversing
Salinity
Add Salt
Service and Service Code
NOTE See "Service Codes" page 33. Problems can range from insuffi cient salinity to the DC cord not connected.
See troubleshooting.
Audible Alarm
NOTE The audible alarm can be permanently disabled by removing the blue jumper from J10 on the control
center front cover PCB.
The
indicator shows that the cell has been turned on by the
CELL ON
control center. Some reasons for the
during normal operation, are:
CHLORINE PRODUCTION
appears during cell rest period,
automatic cleaning cycle, Low temperature cut off has been activated, or
a service related problem such as a salinity level below 2.0 gpl or salinity
level too high.
During the Normal chlorine production cycle when the unit is set for
less than 100% the cell will periodically rest, i.e., not make chlorine.
The
indicator shows that the cell has been turned off by
CELL RESTING
the control center. The reason for the
normal operation, is
CHLORINE PRODUCTION
When the control center determines that water is fl owing past the Flow/
Temp/Salinity Sensor, the
detected, the
NO FLOW
The automatic cleaning cycle of the AquaPure is in progress. The
cleaning cycle is factory set and cannot be adjusted. Cell Reversing does
not interrupt the production of Chlorine.
Salinity is displayed along with the
the
button is depressed. If a reading of HH appears, the salinity
Salinity
is above 4.5 to 6.5 gpl (depending on pool temperature) and is too high to
measure correctly (at normal temperatures). Maintain Salinity between
3.0 and 3.5 gpl. See pages 18 through 21.
The
indicator comes on when the Flow/Temp/Salinity Sensor
ADD SALT
determines that the salinity level of the pool water is too low. Maintain
Salinity between 3.0 and 3.5 gpl.
The
indicator will turn on whenever the AquaPure detects a
SERVICE
problem that requires attention. The
by a service code displayed on the front panel, displayed as a 3 digit
code. The service code(s) are displayed twice per minute with an audible
alarm.
An audible alarm (beep) sounds once per hour, and only for the fi rst
service code when a
Service
cleared by pressing and holding the
audible alarm can be cleared for 24 hours or until the power to the unit
is turned off and back on whichever comes fi rst. However, the audible
alarm will return if a new problem is detected.
CELL ON
CHLORINE PRODUCTION
set to less than 100% and
condition, two minutes before
NO FLOW
CELL RESTING
indicator is displayed. When no fl ow is
FLOW
is displayed and the cell is turned off.
(grams per liter) indicator, when
gpl
indicator is accompanied
SERVICE
condition is detected. The Alarm can be
button
Salinity
Page 23
indicator not being on
set to 00%,
Cell Resting
indicator, during
set to less than 100%.
for 5 seconds. The
C