DHB2PT-44D
Displays & Indicators
1
• The red indicator light next to the UPPER SHELF label
indicates that the temperature being displayed is for the Upper
Heater of the selected cavity.
• The red indicator light next to the PROG label is on when in
the Programming Mode.
• The red indicator light next to the LOWER SHELF label
indicates that the temperature being displayed is for the Lower
Heater of the selected cavity.
• The red indicator light next to the HEAT label is on when
power is applied to the heater zone being displayed on the
control panel.
• The red indicator light next to SET-POINT TEMP label is on
when the Set-Point Temperature is being displayed for the
heater zone being displayed on the control panel.
• The digital display shows the cavity and the associated
temperature or Power On control values, for example:
For Cavity A, the display may show A 35 (percentage of
heater capacity for the Upper Heater).
For Cavity B, the display may show B 40 (percentage of
heater capacity for the Upper Heater).
2
Control Panel Buttons
• SET-POINT: The Set-Point temperature is displayed for the
selected heaters when this button is pressed during the
operating mode. The SET-POINT indicator light is on when the
Set-point mode is selected.
To Program a heater, press and hold the PRINCE CASTLE
button then press and hold the SET-POINT button for 5 secs.
or until the PROG indicator light turns on. Use the UP and
DOWN arrows to change the percentage of heater value for the
Upper and Lower Heaters in Cavities A and B.
The Percentage of Power relates to utilities, and while
increased percentage may be required to hold the
product properly, it should be kept at the lowest
possible setting to save utility consumption.
Printed in USA 05/19 © 2019
Control Panel
• ACTUAL TEMP: ACTUAL TEMP BUTTON DOES NOT
FUNCTION
This is not the actual air temperature, nor will it be the
actual product temperature.
• UP ARROW & DOWN ARROW: When pressed in the operating
mode, selects which heater zone is in the display on the
control panel. The indicator light next to the UPPER SHELF or
LOWER SHELF is on to indicate which heater in the cavity is
selected.
4