Chicken Holding Bin
DHB2PT-44D
Safety Information
Indicates information important to the proper operation of the
unit. Failure to observe may result in damage to the equipment
and/or severe bodily injury or death.
Indicates information important to the operation of the unit.
Failure to observe may result in damage to the equipment.
Remove the unit from the carton and inspect for signs of
damage. If there is damage to the unit:
• Notify the carrier within 24 hours of delivery,
• Save carton and packaging materials for inspection purposes,
Contact your local dealer, or if purchased directly, the Prince
Castle Sales Department at 1-800-722-7853 opt 1 or
630-462-8800 opt 1 to arrange for a replacement unit.
A. Place the bin on a counter or workstation.
1
B. Make power connection to the terminal block on
the top of the bin. Required voltage is 208 TO 240
VOLTS SINGLE PHASE, and the connections are
L1, L2, and Earth Ground (see figure of wiring
diagram).
The bin draws 31 amps at 208 or 35 amps at 240
volts during the 35 min. warm-up.
The current drops to approximately half when the
heaters reach the set-point temperature.
A. Turn the power switches ON.
2
B. Allow 35 mins. for warm-up.
Environmental Issues
3
Airflow through the bin will adversely affect the
performance of the bin. Sources of airflow include:
• Air conditioning vents
• Air currents
• Make-up air Inflows
• Drive-through window
None of the above should be directing airflow towards the
bin or through the cavities of the bin. To check for airflow,
remove a pan from a hot steam table and watch the
direction of the steam coming out of the steam table.
Printed in USA 05/19 © 2019
WARNING
CAUTION

Installation / Setup

Important!

Prince Castle reserves the right to change specifications and
product design without notice. Such revisions do not entitle the
buyer to corresponding changes, improvements, additions or
replacements for previously purchased equipment.
NOTE: When installing this unit, the ambient temperature at the
mounting site should not exceed 37.8°C (100°F).
All electrical connections must be in accordance with local
electrical codes and any other applicable codes.
Plug the unit into an applicable electrical receptacle.
GRN 8AWG
RED 8AWG
The direction the steam flows is an indicator of the airflow
direction and its intensity. There is no airflow if the steam
flows straight up as it dissipates. There is an intense airflow
if the steam quickly changes direction and flows parallel to
the floor.
If there is airflow, check for the source(s). It is recommended
that air diverters be installed to direct the airflow away from
the bin.
Do NOT reduce the amount of cooled air brought into the
building. Direct the flow of air away from the cavities of the
Chicken Holding Bin.