During the first few hours of operation, you may notice a
faint odor. This is normal, and the odor disappears after the
first few hours of use.
The bin is tested and calibrated at the factory before shipment.
However, due to temperature and climate changes during
shipment, the insulation in bin can absorb moisture.
The recommended settings listed below are starting points only.
The final setting for each cavity is influenced by the airflow
through the cavity.
The airflow is influenced by the bins location relative to the
Drive-Through window, the front door, and/or the air
conditioning vents.
The final setting must achieve the required serving temperature
at the end of the hold time.
Therefore, the setting of each cavity may have to be adjusted up
or down from the recommended starting points listed below to
meet the quality and temperature requirements.
A higher setting yields hotter chicken, but in achieving a
hotter temperature, more moisture is driven from the
chicken. Thus, there must be a balance at the end of the
maximum hold time, where the chicken is above a
minimum serving temperature and all quality requirements
are met.

Resetting to Factory Defaults

To revert all settings back to the original factory defaults:
A. Turn the unit off.
B. Press and hold both UP and DOWN arrows.
C. Turn the unit back on and wait 5 secs.
D. Release UP and DOWN arrows.
All previously saved settings are lost upon resetting the
defaults! Use with caution.
528-503 RevJ_EN
Initial Startup
The odor during the first few hours of use is from the drying out
of the insulation (moisture is driven from the insulation's
binders, a starch-like material).
If the florescent lights do not turn on, verify that the bulbs are
seated in their sockets.

Recommended Settings

1
The default Set-Point for the Upper Heater is 60%.
The Lower Heater default is 40% for Cavity A and 60% for
Cavity B.