Parameter list

4.2
Parameter list
4.2.1
Parameter list
For simple variable-speed operation of the inverter, the initial setting of the parameters may be used. Set the necessary
parameters to meet the load and operational specifications. Parameter setting, change and check can be made from the
operation panel.
REMARKS
indicates simple mode parameters.
The parameters surrounded by a black border in the table allow its setting to be changed during operation even if "0" (initial
value) is set in Pr. 77 Parameter write selection.
Func-
Parameter
Name
tion
0
Torque boost
1
Maximum frequency
2
Minimum frequency
3
Base frequency
4
Multi-speed setting (high speed)
5
Multi-speed setting (middle speed)
6
Multi-speed setting (low speed)
7
Acceleration time
8
Deceleration time
9
Electronic thermal O/L relay
10
DC injection brake operation frequency 0 to 120Hz
11
DC injection brake operation time
12
DC injection brake operation voltage
13
Starting frequency
14
Load pattern selection
15
Jog frequency
16
Jog acceleration/deceleration time
17
MRS input selection
18
High speed maximum frequency
19
Base frequency voltage
Acceleration/deceleration reference
20
frequency
22
Stall prevention operation level
Stall prevention operation level
23
compensation factor at double speed
24
Multi-speed setting (speed 4)
25
Multi-speed setting (speed 5)
26
Multi-speed setting (speed 6)
27
Multi-speed setting (speed 7)
Acceleration/deceleration pattern
29
selection
58
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0 to 30%
0.1%
6/4/3/2%
75
∗1
0 to 120Hz
0.01Hz
120Hz
84
0 to 120Hz
0.01Hz
0Hz
84
0 to 400Hz
0.01Hz
60Hz
86
0 to 400Hz
0.01Hz
60Hz
90
0 to 400Hz
0.01Hz
30Hz
90
0 to 400Hz
0.01Hz
10Hz
90
0 to 3600s
0.1s
5/10/15s
97
∗2
0 to 3600s
0.1s
5/10/15s
97
∗2
Rated
0 to 500A
0.01A
inverter
101
current
0.01Hz
3Hz
110
0 to 10s
0.1s
0.5s
110
0 to 30%
0.1%
6/4/2%
110
∗3
0 to 60Hz
0.01Hz
0.5Hz
99
0 to 3
1
0
88
0 to 400Hz
0.01Hz
5Hz
92
0 to 3600s
0.1s
0.5s
92
0, 2, 4
1
0
116
120 to 400Hz
0.01Hz
120Hz
84
0 to 1000V, 8888, 9999
0.1V
9999
86
1 to 400Hz
0.01Hz
60Hz
97
0 to 200%
0.1%
150%
80
0 to 200%, 9999
0.1%
9999
80
0 to 400Hz, 9999
0.01Hz
9999
90
0 to 400Hz, 9999
0.01Hz
9999
90
0 to 400Hz, 9999
0.01Hz
9999
90
0 to 400Hz, 9999
0.01Hz
9999
90
0, 1, 2
1
0
100
Symbol in the Remarks column
...Specifications differ according to the date assembled. Refer to page 298 to check the SERIAL number.
These instruction codes are used for parameter read and write by using Mitsubishi inverter protocol with the RS-485 communication.
(Refer to page 182 for RS-485 communication)
" " indicates valid and "×" indicates invalid of "control mode-based correspondence table", "parameter copy", "parameter clear", and "all parameter clear".
Customer
Parameter
Remarks
Setting
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
22
23
24
25
26
27
29
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
Copy
V/F
V/F
V/F
GP MFVC
GP MFVC
GP MFVC
×
00
80
0
01
81
0
02
82
0
×
03
83
0
04
84
0
05
85
0
06
86
0
07
87
0
08
88
0
09
89
0
0A
8A
0
0B
8B
0
0C
8C
0
0D
8D
0
×
0E
8E
0
0F
8F
0
10
90
0
11
91
0
12
92
0
×
13
93
0
14
94
0
16
96
0
17
97
0
18
98
0
19
99
0
1A
9A
0
1B
9B
0
1D
9D
0