4.21.4 Current average value monitor signal (Pr. 555 to Pr. 557)

The average value of the output current during
constant speed operation and the maintenance timer
value are output as a pulse to the current average
value monitor signal (Y93).
The pulse width output to the I/O module of the
programmable controller or the like can be used as a
guideline to know abrasion of machines, elongation of
belt and the maintenance time for aged deterioration
of devices.
The current average value monitor signal (Y93) is
output as pulse for 20s as 1 cycle and repeatedly
output during constant speed operation.
Parameter
Name
Number
555
Current average time
556
Data output mask time
Current average value
557
monitor signal output
reference current
The above parameters can be set when Pr. 160 Extended function display selection = "0". (Refer to page 163)
The above parameters allow their settings to be changed during operation in any operation mode even if "0" (initial value) is set in Pr. 77 Parameter write selection.
Y93 signal
1) Data output mask time
When the speed has changed to
constant from acceleration/deceleration,
Y93 signal is not output for Pr. 556 time.
2) Start pulse
Output as Hi pulse shape for 1s (fixed)
The output currents are averaged during
the time period set in Pr. 555.
3) Output current average value pulse
The averaged current value is output for 0.5 to 9s
(10 to 180%) during start pulse output.
Signal output time =
The pulse output of the current average value monitor signal (Y93) is shown above.
For the terminal used for the Y93 signal output, assign the function by setting "93" (positive logic) or "193" (negative logic)
to any of Pr. 190 or Pr. 197 (Output terminal function selection). The function can not be assigned to Pr. 192 A,B,C terminal
function selection.
1) Setting of Pr. 556 Data output mask time
The output current is unstable (transient state) right after the operation is changed from the acceleration/deceleration state
to the constant speed operation. Set the time for not obtaining (mask) transient state data in Pr. 556.
Initial Value
1s
0s
Rated
inverter
current
From acceleration to constant speed operation
Output current average value (A)
Pr. 557 (A)
Programmable controller
Maintenance
time
Parts have
reached their life
Setting Range
Time taken to average the current during start pulse
0.1 to 1s
output (1s).
0 to 20s
Time for not obtaining (mask) transient state data.
Reference (100%) for outputting the signal of the
0 to 500A
current average value.
Output frequency
1 cycle (20s)
4) Maintenance timer pulse
The maintenance timer value (Pr. 503) is
output as Hi pulse shape for 2 to 9s
(16000h to 72000h)
Signal output time =
5s
Useful functions
Output unit
Input unit
Inverter
Description
Time
Next cycle
5) End pulse
Output as low pulse
shape for 1 to 16.5s
Pr. 503 100h
5s
40000h
4
233