Alarm recording Tab — Setting the
Image memory function when
detecting the alarm
You can set to record the image and audio file to the
memory linked with the external sensor input or with the
built-in object detection function.
Alarm recording
Select On to record the image and audio file in the built-
in memory, ATA memory card or CF memory card,
linked with alarm detection.
Image file name
Type the file name you want to assign to the images to
be recorded. You can use up to 10 alphanumeric
characters, - (hyphen) and _ (underscore) for naming.
Suffix
Select a suffix to be added to the file name.
Date & time: The Date & time suffix is added to the
image file name.
The Date & time suffix consists of lower two-digits
of the year (2 digits), month (2 digits), date (2 digits),
hour (2 digits), minute (2 digits), second (2 digits)
and consecutive number (2 digits), thus adding a 14-
digit number to the image file name.
Sequence number: A consecutive number of 10 digits
between 0000000001 and 4294967295 and an
consecutive 2 digits number is added to the image
file name.
Tip
A consecutive number added to Date & time and
Sequence number is used to identify each of the
multiple files created with consecutive alarm events.
Sequence number clear
Click Clear to reset the Sequence number suffix to 1.
Alarm
Select the alarm to be linked with the recording of image
and audio files.
Sensor input 1: The external sensor that is connected to
sensor input 1 of the camera I/O port.
Sensor input 2: The external sensor that is connected to
sensor input 2 of the camera I/O port.
Object detection: The alarm by the object detection
function.
Click Detection, and the Object detection menu is
displayed to allow you to set the object detection
function (page 82).
Note
In the case that the synchronized preset position is
specified in Position at alarm in the Preset position
menu, the alarm event that happens when the camera
moves to the preset position will be invalid.
Effective period
Set the period during which alarm detection is effective.
Always: The alarm detection is always effective.
Schedule: You can specify the period during which
alarm detection is effective.
Click Schedule and the setting menu for the effective
period is displayed. ("Setting the Schedule —
Schedule Menu" on page 80)
Alarm buffer
Select Use alarm buffer when you record the image/
audio of before and after alarm detection (pre-alarm,
post-alarm).
If you do not select the alarm buffer, only the image at
the moment of the alarm detection is recorded.
Click Alarm buffer to display the Alarm buffer menu.
For details, see "Setting the Alarm Buffer — Alarm
buffer Menu" on page 81.
Note
This setting becomes invalid and a still image is
recorded if H.264 is selected in the Video codec tab of
the Camera menu.
OK/Cancel
See "Buttons common to every menu" on page 31.
Recording Images in Memory — Image memory Menu
73

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snc-rz50n - ip network cam 26x pan tilt zoom ms pc card slotSnc-rz50pIpela snc-rz50p

Table of Contents