Mass Storage Devices; With Raid System; Without Raid System - ADS-tec OPD9016 Instruction Manual

Table of Contents

Advertisement

OPC9000 series − Instruc�on manual v1.5

7.5 Mass storage devices

Information on how to install or remove SSD cards is available in section 10.4.

7.5.1 With RAID system

The device supports two separate SSD mass storage devices that can be used together with the help of
RAID technology (RAID = redundant array of independent disks).
To use this function, two type M.2 2242 Key M SSD cards with a SATA interface are required.
NVMe cards with a PCIe interface cannot be used.
Supported options:
RAID level 0 striping: this RAID variant is recommended when a large data storage system with
high data access speeds is required. Since the data are not stored redundantly, this level is only
recommended if data loss will not result in serious consequences, e.g. because the data can be
recovered easily if a storage medium fails.
RAID level 1 mirroring: both mass storage devices redundantly store the same data in this case. If
a mass storage device fails, usually no data is lost and the defective mass storage device can easily
be replaced. The total storage size corresponds to the smallest of the individual storage devices
used.
The desired RAID level must be specified when placing the order.

7.5.2 Without RAID system

The devices can also be ordered with two SSD mass storage devices, but without a RAID system.
By default, the operating system is then located on the mass storage device next to the CMOS battery.
The second mass storage serves as a data partition.
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nür�ngen • Germany
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Opc9000 seriesOpd9019Opd9024

Table of Contents