Table of Contents

Advertisement

OPC9000 series − Instruc�on manual v1.5

7.4 CAN card

The optional CAN bus card from PEAK features two separate CAN buses connected together via a
9-pin Sub-D connector. The two buses are galvanically isolated from each other and from the device's
electrical system.
Standards: the card supports CAN FD and is backwards compatible with the CAN standard 2.0 A/B.
Transmission rate: max. 1 Mbit/s per bus.
Please note that the maximum bus length depends on the set transmission rate. Typical values with
correct termination:
Transmission rate
1 Mbit/s
500 kbit/s
250 kbit/s
125 kbit/s
50 kbit/s
25 kbit/s
15 kbit/s
Devices delivered ex factory with the Windows operating system and CAN card already include the
appropriate drivers pre-installed.
For other cases, and if special configuration or programming software is required for the fieldbus nodes,
see
https://www.peak-system.com/
Connector pin assignment and termination information is available in section 5.3.4.
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nür�ngen • Germany
Bus length
40 m
110 m
240 m
500 m
1.3 km
2.5 km
5 km
32

Advertisement

Table of Contents
loading

This manual is also suitable for:

Opc9000 seriesOpd9019Opd9024

Table of Contents