Advertisement

Quick Links

Version
2.0
User Manual
Industrial PCs
OPC6115/6315

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the opc6115 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADS-tec opc6115

  • Page 1 Version User Manual Industrial PCs OPC6115/6315...
  • Page 2: Table Of Contents

    Installing add-on cards 5 Commissioning 5.1 Available Interfaces 5.2 Cable installation Order of Steps during Commissioning 5.4 Check for operational Readiness 6 Operation 6.1 Front Control Keys 6.2 Softkeyboard 6.3 TouchScreen 6.4 Status Indicators © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 3 9.1.4 USB-Lock Function 9.1.5 On/Off Button Configuration 9.1.6 Exemplary RFID Application 9.1.7 Softkeyboard 9.1.8 Screen Mob 9.1.9 Softkeyboard 10 Technical Details 11 Service & Support 11.1 ads-tec Support 11.2 Company adress © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 4: Remarks

    Contains information for installation, commissioning and operating the device along with technical data of the device hardware. Website: By using the website www.ads-tec.de, you can download drivers, software, user manuals, leaflets and flyers from the Download section on the website. Note: We would recommend you make use of our website contents (www.ads-tec.de) in...
  • Page 5: Trademarks

    Any reproduction, translation as well as electronic and photographic archiving and modification shall only be permitted after explicit written authorisation by ads-tec GmbH. Any party in violation of this provision shall be obliged to damage compensation. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 6: Environmental Conditions

    1.6 Environmental Conditions The device may be operated under the following conditions. Failure to observe these specifications will terminate any warranty for this device. Ads-tec cannot be held liable for any damages arising due to improper use and handling. ...
  • Page 7: Standards

    / forklift equipment. Platform including a hard disc: Equipped with a hard disc for stationary use, e.g. in the manufacturing department using a standard operating system. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 8: Scope Of Delivery

     With 24 V DC devices: 3-pin COMBICON plug from Phoenix Contact: COMBICON MC 2,5/3-STF-5,08 (already plugged in the device socket)  Installation kit for installation Optional Scope of delivery:  Operating System © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 9: Notes On Operation & Safety

    Avoid overheating during unit operations; the unit must not be exposed to direct sunlight or any other direct light or heat sources. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 10: Damage Caused By Improper Use

    Note: Always adhere to the safety measures applicable when handling components at risk of being destructed by electrostatic discharges.. (DIN EN 61340-5-1 / DIN EN 61340-5-2) © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 11: Mounting

    PCBs must be taken into account. The enclosure must be calculated in such a way that the maximum environmental temperature is not exceeded in any case. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 12: External Device Dimensions Opc6115

    OPC6115/6315 3.2 External Device Dimensions OPC6115 © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 13 OPC6115/6315 Abb. 1: © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 14: External Device Dimensions Opc6315

    OPC6115/6315 3.3 External Device Dimensions OPC6315 © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 15 OPC6115/6315 Abb. 2: © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 16: Mounting Procedure

    If additional grounding conductors are attached to a grounding screw, a wire diameter of at least 2.5 mm² is specified. © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 17: Add-On Card Installation

    •Reconnect the grounding conductor if it has been removed and replace the cover while paying attention to the side clips as the case may be. •Tighten all of the screws on the cover again. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 18: Commissioning

    If you want to have the device electrically insulated from the power supply, you have to use a method of installation that ensures appropriate insulation. Pos: 18 /Datentechnik/Inbetriebnahme/Reihenfolge der Inbetriebnahme/Reihenfolge der Inbetriebnahme für VMT 60xx-Serie @ 1\mod_1222073159179_6.doc @ 4100 @ © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 19: Cable Installation

    (e.g. smoke development from the device, etc.). If any damage is detected, the device must be put out of service immediately and protected from accidental switch-on. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 20: Operation

    The controller display will not be output on the display, in this case. The key functions can be modified in accordance with customer specific requirements. Above described functions are pre-set ex works. © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 21 In the BIOS setup, the key to how the right button acts on a keyboard. With this combination, switch them on without power button. Power ON Pos: 21 /Datentechnik/Bedienung/Softkeyboard/Softkeyboard für VMT 60xx @ 1\mod_1228750145198_6.doc @ 4251 @ © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 22: Softkeyboard

    When deactivating the soft keyboard, the previously active state (alphanumeric / numeric keys or function keys) will be stored and will be displayed when re-activating the keyboard. Pos: 22 /Datentechnik/Bedienung/Touch Screen/Touch Screen für VMT 60xx @ 1\mod_1246361069977_6.doc @ 5853 @ © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 23: Touchscreen

    The device is ready for operation (Power ON).  LED is off The device is switched off. (POWER OFF) Pos: 25 /Datentechnik/Schnittstellen/Schnittstelleneinstellung/Schnittstelleneinstellung für VMT-Serie / PLC 500 @ 0\mod_1158916296612_6.doc @ 517 @ © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 24: Interfaces

    This also applies if the device is installed by using a metal retainer clip. If you want to have the device electrically insulated from the power supply, you have to use a method of installation that ensures appropriate insulation. © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 25: 115/230V Ac Power Supply

    • current consumption: 1,2A (115V) / 0,6A (230V) • Max. Input current: 30A (115) / 60A (230V) Note: The typical power consumption of this device is indicated in the "Technical details" chapter. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 26: Speakers

    The volume can be set up by using the device front keys. When activating the described key combinations, the volume level is modified. If the soft keyboard is installed, the system volume is additionally displayed by a display bar. © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 27: Usb-Interface

    The cover has a tab on the right-hand side, which is used for opening. The plastic cover of the USB interface must be returned in protective position after use. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 28: Ps/2 Interface

    Specifications of this network topology must be observed in this case. You can install the drivers required for functioning from the enclosed service CD, should they not be installed on the device. Pin-Number Signal-Name TX + TX - RX + RX - © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 29: Serial Com Interface (Rs232)

    A subsequent restart of the computer might be required in order to properly activate this function.. Pin-Number Signal-Name RI oder + 5V DC (max. 1 A) Note: This interface is not electrically isolated. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 30: Dvi- Interface

    Hot Plug Detect TMDS Data0- TMDS Data0+ TMDS Data0/5 Shield TMDS Clock Shield TMDS Clock+ TMDS Clock- Analog Red Analog Green Analog Blue Analog Horizontal Sync Analog GND Return: (analog R, G, B) © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 31 OPC6115/6315 © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 32: Drives

    Data loss might result in the event of non-compliance! Pos: 36 /Datentechnik/Software / Treiber Installation/Installation des Betriebssystems/Installation des Bertiebssystems für VMT60xx @ 2\mod_1263211380903_6.doc @ 6940 @ © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 33: Software-/Driver-Installation

    With Windows CE 6.0 or Windows XP embedded, a complete image can also be installed by using a USB stick. Pos: 37 /Datentechnik/Software / Treiber Installation/Touch Screen/Touch Screen Installation für OPC 5112/5212/5315/5515/5317/5319 / CPC5006/OTC5006/ VMT-Serie @ 0\mod_1159175108636_6.doc @ 665 @ © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 34 If the cursor position perfectly matches the touch point of your finger, you can exit this control menu by pushing "OK". © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 35: Configuration Center

    9.1 Configuration Center Configuration The start page of the Configuration Center provides you with an overview of which ads-tec applications are installed on the device. Additionally, you can start any of these applications from the Configuration Center by double-clicking on it...
  • Page 36: Automatic Brightness Adaption

    In order to save the changes, you'll have to push either Save or OK. © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 37: Com Input Configuration

    The ignition application allows the control of the VMT6 device ignition function. If the status is set to Enabled, the device is switched off after expiry of the preset period of time. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 38: Usb-Lock Function

    In this case, the settings can only be modified if the password was entered correctly. USB Ports The desired USB ports can individually be locked by using the Lock button. All changes must be confirmed with the Save button. © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 39: On/Off Button Configuration

    The ON / OFF pushbutton only switches the device on. The switch-off function is disabled Note: If the secure mode is used, the device can only be shut down by the software. © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 40: Exemplary Rfid Application

    9.1.7 Softkeyboard Here you can configure the soft keyboard application. A large variety of settings, like layout or commands can individually be adapted. All changes must be confirmed by pushing the Save button.. © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 41: Screen Mob

    You can make further changes to the basic settings of the soft keyboard, if required. More information about this topic you'll find in the "Readme" file in the installation folder for the soft keyboard! © ads-tec GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen...
  • Page 42: Technical Details

    390 x 312 x 93 mm 390 x 312 x 152 mm x T) Weight 7,5 kg 7,5 kg Power consumption 130W (typ) 150W (typ) Pos: 40 /Datentechnik/Service und Support/Service & Support @ 2\mod_1254312498746_6.doc @ 6472 @ © ads-tec GmbH • Heinrich-Hertz-Str. 1 •72622 Nürtingen...
  • Page 43: Service & Support

    11.1 ads-tec Support The ads-tec support team is available for phone calls from direct clients from Monday to Friday from 8:30 AM to 5:00 PM by using the following phone number: Phone: +49 (0) 7022 2522-202...

This manual is also suitable for:

Opc6315

Table of Contents